Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

68

matching recommendations
Reset
SIC 239 Misc. Fabricated Textile Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0203 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $994 $1,896 Implemented
MO0203 # 08 Y:1997 08 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $993 $40 Not Implemented
MO0203 # 09 Y:1997 09 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $606 $51 Implemented
MO0203 # 10 Y:1997 10 1997 USE RE-USABLE FILTERS $4,451 $1,360 Not Implemented
MO0203 # 11 Y:1997 11 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $4,596 $5,360 Not Implemented
MO0203 # 07 Y:1997 07 1997 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $329 $963 Implemented
KU0458 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,935 $4,856 Implemented
KU0458 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $780 $257 Implemented
KU0458 # 05 Y:1996 05 1996 INSTALL OCCUPANCY SENSORS $1,402 $850 Implemented
KU0458 # 03 Y:1996 03 1996 RECOVER AND REUSE WASTE MATERIAL $6,111 $0 Implemented
KU0458 # 02 Y:1996 02 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $35,563 $2,800 Implemented
KU0458 # 01 Y:1996 01 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $50,368 $147,448 Not Implemented
MO0094 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,764 $35,485 Implemented
MO0094 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,472 $1,418 Implemented
MO0094 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,784 $9,001 Not Implemented
MO0094 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $676 $1,605 Not Implemented
MO0094 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $610 $690 Not Implemented
MO0094 # 06 Y:1993 06 1993 USE OPTIMUM TEMPERATURE $528 $200 Implemented