289
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0029 # 04 Y:1995 | 04 | 1995 | USE PHOTOCELL CONTROLS | $822 | $95 | Not Implemented |
NV0029 # 05 Y:1995 | 05 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,747 | $2,202 | Not Implemented |
NV0029 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $755 | $1,020 | Not Implemented |
SF0057 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,829 | $2,843 | Implemented |
SF0057 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $6,431 | $11,418 | Not Implemented |
SF0057 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $40,803 | $27,430 | Not Implemented |
SF0057 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,611 | $250 | Implemented |
SF0057 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,669 | $1,510 | Implemented |
SF0057 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $3,137 | $4,459 | Not Implemented |
SF0057 # 07 Y:1995 | 07 | 1995 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $17,555 | $37,000 | Not Implemented |
SF0057 # 08 Y:1995 | 08 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $142,905 | $479,000 | Not Implemented |
NV0017 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,998 | $0 | Implemented |
NV0017 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,930 | $888 | Implemented |
NV0017 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,689 | $200 | Implemented |
NV0017 # 04 Y:1995 | 04 | 1995 | REDUCE GLAZED AREAS IN BUILDINGS | $151 | $653 | Not Implemented |
NV0017 # 05 Y:1995 | 05 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,560 | $0 | Not Implemented |
SD0051 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,002 | $1,890 | Implemented |
SD0051 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,549 | $3,320 | Implemented |
SD0051 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $223 | $20 | Not Implemented |
SD0051 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $544 | $80 | Not Implemented |
SD0051 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $102 | $0 | Implemented |
SD0051 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $771 | $1,080 | Implemented |
SD0051 # 07 Y:1993 | 07 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,314 | $2,080 | Implemented |
SD0051 # 08 Y:1993 | 08 | 1993 | USE PHOTOCELL CONTROLS | $907 | $1,715 | Not Implemented |
OR0133 # 01 Y:1991 | 01 | 1991 | INSTALL SET-BACK TIMERS | $1,035 | $0 | Implemented |