Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0380 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,389 | $29,590 | Not Implemented |
OR0380 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,954 | $30,046 | Implemented |
OR0380 # 04 Y:2000 | 04 | 2000 | OPTIMIZE PLANT POWER FACTOR | $4,853 | $13,600 | Implemented |
OR0380 # 05 Y:2000 | 05 | 2000 | USE PHOTOCELL CONTROLS | $3,605 | $605 | Implemented |
OR0380 # 06 Y:2000 | 06 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $647 | $0 | Implemented |
OR0380 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,013 | $0 | Not Implemented |
OR0380 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,344 | $7,500 | Not Implemented |
OR0379 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,383 | $7,000 | Implemented |
OR0379 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $9,673 | $15,010 | Not Implemented |
OR0379 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,146 | $0 | Not Implemented |
OR0379 # 04 Y:2000 | 04 | 2000 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,099 | $885 | Implemented |
OR0379 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,229 | $0 | Not Implemented |
OR0379 # 06 Y:2000 | 06 | 2000 | COMBINE UTILITY METERS | $1,715 | $4,000 | Not Implemented |
OR0379 # 07 Y:2000 | 07 | 2000 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $9,628 | $48,484 | Implemented |
OR0379 # 08 Y:2000 | 08 | 2000 | OPTIMIZE PLANT POWER FACTOR | $7,013 | $19,600 | Not Implemented |
OR0379 # 09 Y:2000 | 09 | 2000 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $1,026,000 | $1,337,500 | Not Implemented |
OR0374 # 01 Y:2000 | 01 | 2000 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $152,880 | $600,000 | Not Implemented |
OR0374 # 02 Y:2000 | 02 | 2000 | USE PHOTOCELL CONTROLS | $2,537 | $1,000 | Not Implemented |
OR0374 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,481 | $18,298 | Implemented |
OR0374 # 04 Y:2000 | 04 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $145 | $500 | Not Implemented |
OR0378 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,287 | $1,000 | Implemented |
OR0378 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $2,967 | $4,000 | Implemented |
OR0378 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $732 | $0 | Implemented |
OR0378 # 04 Y:2000 | 04 | 2000 | OPTIMIZE PLANT POWER FACTOR | $2,340 | $6,500 | Not Implemented |
OR0378 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,503 | $4,033 | Implemented |