Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0478 # 04 Y:2000 | 04 | 2000 | INSULATE FEEDWATER TANK | $3,300 | $2,500 | Implemented |
MA0478 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $50,450 | $222,000 | Not Implemented |
MA0478 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $9,000 | $40,000 | Not Implemented |
MA0478 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $6,350 | $5,500 | Implemented |
MA0478 # 05 Y:2000 | 05 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,960 | $0 | Implemented |
MA0478 # 06 Y:2000 | 06 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,870 | $13,000 | Not Implemented |
MA0478 # 07 Y:2000 | 07 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,000 | $550 | Implemented |
MA0478 # 08 Y:2000 | 08 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,244 | $0 | Not Implemented |
MA0478 # 09 Y:2000 | 09 | 2000 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,080 | $2,000 | Not Implemented |
MA0478 # 10 Y:2000 | 10 | 2000 | INSTALL OCCUPANCY SENSORS | $320 | $450 | Implemented |
ME0295 # 10 Y:2000 | 10 | 2000 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $27,000 | $1,512 | Not Implemented |
ME0295 # 01 Y:2000 | 01 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,961 | $72,500 | Not Implemented |
ME0295 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,533 | $20,900 | Not Implemented |
ME0295 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,918 | $11,100 | Not Implemented |
ME0295 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,043 | $860 | Not Implemented |
ME0295 # 05 Y:2000 | 05 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,424 | $210 | Not Implemented |
ME0295 # 06 Y:2000 | 06 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,656 | $1,330 | Not Implemented |
ME0295 # 07 Y:2000 | 07 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $815 | $1,600 | Not Implemented |
ME0295 # 08 Y:2000 | 08 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $112 | $130 | Not Implemented |
ME0295 # 09 Y:2000 | 09 | 2000 | MAKE A NEW BY-PRODUCT | $15,041 | $21,330 | Not Implemented |
MA0363 # 07 Y:1996 | 07 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $410 | $0 | Implemented |
MA0363 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $723 | $700 | Not Implemented |
MA0363 # 05 Y:1996 | 05 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $1,801 | $4,300 | Not Implemented |
MA0363 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,549 | $325 | Implemented |
MA0363 # 03 Y:1996 | 03 | 1996 | USE POWER DURING OFF-PEAK PERIODS | $7,680 | $0 | Not Implemented |