Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,223
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OKO952 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,312 | $0 | Implemented |
OKO952 # 08 Y:2016 | 08 | 2016 | INSTALL SET-BACK TIMERS | $151 | $160 | Not Implemented |
BS0088 # 01 Y:2016 | 01 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,541 | $11,782 | Not Implemented |
BS0088 # 02 Y:2016 | 02 | 2016 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $64,374 | $480 | Not Implemented |
BS0088 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,994 | $29,692 | Not Implemented |
BS0087 # 01 Y:2016 | 01 | 2016 | OPTIMIZE PLANT POWER FACTOR | $32,576 | $43,711 | Not Implemented |
BS0087 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,907 | $27,896 | Not Implemented |
BS0087 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,873 | $275 | Not Implemented |
BS0087 # 04 Y:2016 | 04 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $689 | $5,040 | Not Implemented |
BS0084 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,444 | $31,350 | Not Implemented |
BS0084 # 02 Y:2016 | 02 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,854 | $15 | Not Implemented |
BS0084 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,738 | $825 | Not Implemented |
BS0084 # 04 Y:2016 | 04 | 2016 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $751 | $243 | Not Implemented |
BS0084 # 05 Y:2016 | 05 | 2016 | INSULATE BARE EQUIPMENT | $118 | $264 | Not Implemented |
OR0676 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,742 | $0 | Not Implemented |
OR0676 # 02 Y:2016 | 02 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,729 | $6,828 | Not Implemented |
OR0676 # 03 Y:2016 | 03 | 2016 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $216,607 | $80,000 | Implemented |
OR0676 # 04 Y:2016 | 04 | 2016 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,774 | $7,200 | Implemented |
OR0676 # 05 Y:2016 | 05 | 2016 | ADD AREA LIGHTING SWITCHES | $1,356 | $1,062 | Implemented |
OR0676 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $2,884 | $6,584 | Implemented |
BS0082 # 01 Y:2016 | 01 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $1,327 | $3,476 | Implemented |
BS0082 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,517 | $2,325 | Implemented |
BS0082 # 03 Y:2016 | 03 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $146 | $300 | Implemented |
BS0082 # 04 Y:2016 | 04 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $366 | $2,240 | Not Implemented |
BS0082 # 05 Y:2016 | 05 | 2016 | REDESIGN PROCESS | $1,906 | $1,953 | Implemented |