Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

210

matching recommendations
Reset
SIC 24 Lumber And Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0487 # 03 Y:1993 03 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $419 $0 Not Implemented
TN0487 # 04 Y:1993 04 1993 USE SYNTHETIC LUBRICANT $114 $0 Implemented
TN0487 # 05 Y:1993 05 1993 OPTIMIZE PLANT POWER FACTOR $25,200 $8,300 Not Implemented
TN0487 # 06 Y:1993 06 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,980 $0 Not Implemented
TN0392 # 01 Y:1990 01 1990 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $258,435 $0 Not Implemented
TN0392 # 02 Y:1990 02 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $5,052 $9,401 Implemented
TN0392 # 03 Y:1990 03 1990 REPAIR AND ELIMINATE STEAM LEAKS $2,222 $4,000 Implemented
TN0392 # 04 Y:1990 04 1990 INSTALL SET-BACK TIMERS $12,329 $0 Implemented
TN0392 # 05 Y:1990 05 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $524 $2,000 Implemented
TN0392 # 06 Y:1990 06 1990 ADJUST VENTS TO MINIMIZE ENERGY USE $10,842 $4,670 Implemented
TN0392 # 07 Y:1990 07 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,374 $1,000 Implemented
TN0392 # 08 Y:1990 08 1990 KEEP LAMPS AND REFLECTORS CLEAN $6,631 $9,913 Not Implemented
TN0392 # 09 Y:1990 09 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,692 $2,250 Not Implemented
TN0392 # 10 Y:1990 10 1990 INSTALL TIMERS AND/OR THERMOSTATS $2,859 $760 Implemented
TN0392 # 11 Y:1990 11 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $952 $490 Implemented
TN0392 # 12 Y:1990 12 1990 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $451 $1,740 Not Implemented
TN0392 # 13 Y:1990 13 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $343 $289 Not Implemented
TN0398 # 01 Y:1990 01 1990 INSTALL TIMERS AND/OR THERMOSTATS $11,814 $1,500 Implemented
TN0398 # 02 Y:1990 02 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,396 $930 Not Implemented
TN0398 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,211 $870 Implemented
TN0398 # 04 Y:1990 04 1990 IMPROVE LUBRICATION PRACTICES $1,250 $1,980 Not Implemented
TN0398 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $913 $0 Implemented
TN0398 # 06 Y:1990 06 1990 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $601 $535 Not Implemented
TN0398 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $458 $380 Implemented
TN0378 # 01 Y:1989 01 1989 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $342,613 $1,000,000 Not Implemented