Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
289
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0198 # 12 Y:1998 | 12 | 1998 | USE LESS WASTEFUL PACKAGING | $5,600 | $0 | Not Implemented |
SD0198 # 13 Y:1998 | 13 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,550 | $0 | Not Implemented |
SD0198 # 14 Y:1998 | 14 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,674 | $3,980 | Not Implemented |
SD0198 # 15 Y:1998 | 15 | 1998 | INCREASE USE OF AUTOMATION | $3,258 | $3,300 | Not Implemented |
SD0198 # 16 Y:1998 | 16 | 1998 | INCREASE USE OF AUTOMATION | $39,024 | $6,000 | Not Implemented |
NV0096 # 01 Y:1998 | 01 | 1998 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,487 | $6,000 | Not Implemented |
NV0096 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $248 | $200 | Implemented |
NV0096 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $5,011 | $16,200 | Not Implemented |
NV0096 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,858 | $3,052 | Implemented |
NV0096 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $1,575 | $530 | Not Implemented |
NV0096 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $878 | $611 | Not Implemented |
NV0096 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $306 | Implemented |
NV0096 # 08 Y:1998 | 08 | 1998 | USE PHOTOCELL CONTROLS | $713 | $290 | Not Implemented |
NV0096 # 09 Y:1998 | 09 | 1998 | USE PHOTOCELL CONTROLS | $2,820 | $580 | Not Implemented |
NV0096 # 10 Y:1998 | 10 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $252 | $150 | Not Implemented |
NV0096 # 11 Y:1998 | 11 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $326 | $0 | Not Implemented |
NV0096 # 12 Y:1998 | 12 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $129,993 | $113,670 | Not Implemented |
NV0096 # 13 Y:1998 | 13 | 1998 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $1,500 | $0 | Not Implemented |
NV0095 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,185 | $276 | Not Implemented |
NV0095 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $117 | $75 | Implemented |
NV0095 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,650 | $244 | Not Implemented |
NV0095 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $494 | $398 | Implemented |
NV0095 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,127 | $200 | Implemented |
NV0095 # 06 Y:1997 | 06 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,154 | $200 | Implemented |
NV0095 # 07 Y:1997 | 07 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $12,821 | $5,600 | Implemented |