Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
265
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0126 # 07 Y:1997 | 07 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $66,010 | $220,000 | Not Implemented |
NC0126 # 08 Y:1997 | 08 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $962 | $2,400 | Not Implemented |
NC0126 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $888 | $1,314 | Implemented |
NC0126 # 10 Y:1997 | 10 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,268 | $9,150 | Not Implemented |
NC0126 # 11 Y:1997 | 11 | 1997 | ADD AREA LIGHTING SWITCHES | $3,197 | $2,420 | Not Implemented |
NC0126 # 12 Y:1997 | 12 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143 | $180 | Implemented |
NC0126 # 13 Y:1997 | 13 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $322 | $240 | Not Implemented |
NC0100 # 01 Y:1996 | 01 | 1996 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $307,788 | $815,000 | Not Implemented |
NC0100 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $260,000 | $0 | Implemented |
NC0100 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,693 | $1,795 | Implemented |
NC0100 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,991 | $3,200 | Not Implemented |
NC0100 # 05 Y:1996 | 05 | 1996 | USE PHOTOCELL CONTROLS | $3,024 | $440 | Not Implemented |
NC0100 # 06 Y:1996 | 06 | 1996 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,547 | $0 | Not Implemented |
NC0100 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,271 | $5,040 | Not Implemented |
NC0100 # 08 Y:1996 | 08 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $17,000 | $850 | Implemented |
NC0100 # 09 Y:1996 | 09 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $150 | $100 | Implemented |
OD0045 # 01 Y:1995 | 01 | 1995 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,747 | $704 | Not Implemented |
OD0045 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $1,115 | $394 | Implemented |
OD0045 # 03 Y:1995 | 03 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $4,702 | $0 | Implemented |
OD0045 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,130 | $13,131 | Implemented |
OD0045 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $96 | $57 | Implemented |
OD0045 # 06 Y:1995 | 06 | 1995 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $2,641 | $0 | Not Implemented |
OD0045 # 07 Y:1995 | 07 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $480 | $160 | Implemented |
NC0063 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $776 | $480 | Implemented |
NC0063 # 02 Y:1995 | 02 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $740 | $95 | Implemented |