Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
66
matching recommendationsSIC | 242 | Sawmills And Planing Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0646 # 06 Y:2020 | 06 | 2020 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,817 | $6,709 | Not Implemented |
NC0646 # 05 Y:2020 | 05 | 2020 | OPTIMIZE PLANT POWER FACTOR | $2,484 | $7,500 | Not Implemented |
NC0646 # 04 Y:2020 | 04 | 2020 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $694 | $362 | Implemented |
NC0646 # 03 Y:2020 | 03 | 2020 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $188 | $83 | Not Implemented |
NC0646 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $225 | $778 | Not Implemented |
NC0646 # 01 Y:2020 | 01 | 2020 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $377,240 | $300,000 | Implemented |
NC0545 # 15 Y:2015 | 15 | 2015 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $5,331 | $14,100 | Not Implemented |
NC0545 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,534 | $30,000 | Implemented |
NC0545 # 19 Y:2015 | 19 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,003 | $93 | Not Implemented |
NC0545 # 18 Y:2015 | 18 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,205 | $4,256 | Implemented |
NC0545 # 17 Y:2015 | 17 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $218 | $100 | Not Implemented |
NC0545 # 16 Y:2015 | 16 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $192 | $221 | Not Implemented |
NC0545 # 04 Y:2015 | 04 | 2015 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,565 | $2,400 | Not Implemented |
NC0545 # 14 Y:2015 | 14 | 2015 | REDUCE FLUID FLOW RATES | $8,008 | $11,000 | Not Implemented |
NC0545 # 13 Y:2015 | 13 | 2015 | USE PHOTOCELL CONTROLS | $1,636 | $700 | Not Implemented |
NC0545 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $189 | $48 | Implemented |
NC0545 # 11 Y:2015 | 11 | 2015 | INSTALL OCCUPANCY SENSORS | $261 | $497 | Not Implemented |
NC0545 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $278 | Implemented |
NC0545 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,889 | $30,733 | Implemented |
NC0545 # 02 Y:2015 | 02 | 2015 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,151 | $2,000 | Implemented |
NC0545 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,106 | $100 | Implemented |
NC0545 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,072 | $3,600 | Not Implemented |
NC0545 # 03 Y:2015 | 03 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,703 | $4,873 | Not Implemented |
NC0545 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,473 | $16,125 | Not Implemented |
NC0545 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,690 | $100 | Not Implemented |