Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
398
matching recommendationsSIC | 242 | Sawmills And Planing Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0126 # 03 Y:1991 | 03 | 1991 | INSULATE BARE EQUIPMENT | $3,443 | $2,519 | Implemented |
OR0126 # 04 Y:1991 | 04 | 1991 | INSULATE FEEDWATER TANK | $407 | $356 | Implemented |
OR0126 # 05 Y:1991 | 05 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,690 | $2,500 | Implemented |
OR0126 # 06 Y:1991 | 06 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,283 | $27,444 | Implemented |
OR0126 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $278 | $773 | Implemented |
OR0129 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,102 | $0 | Implemented |
OR0129 # 02 Y:1991 | 02 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,277 | $0 | Implemented |
OR0129 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,236 | $30,000 | Implemented |
OR0129 # 04 Y:1991 | 04 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,626 | $0 | Implemented |
OR0129 # 05 Y:1991 | 05 | 1991 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,068 | $3,066 | Implemented |
OR0129 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,072 | $0 | Implemented |
OR0129 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,573 | $40,000 | Implemented |
OR0129 # 08 Y:1991 | 08 | 1991 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $522 | $864 | Implemented |
OR0129 # 09 Y:1991 | 09 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $790 | $1,430 | Implemented |
OR0129 # 10 Y:1991 | 10 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,172 | $0 | Implemented |
OR0129 # 11 Y:1991 | 11 | 1991 | OPTIMIZE PLANT POWER FACTOR | $12,146 | $26,250 | Implemented |
OR0129 # 12 Y:1991 | 12 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $952 | $2,150 | Implemented |
OR0129 # 13 Y:1991 | 13 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,521 | $15,000 | Implemented |
OR0129 # 14 Y:1991 | 14 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,227 | $64,975 | Implemented |
OR0112 # 01 Y:1991 | 01 | 1991 | INSULATE FEEDWATER TANK | $976 | $532 | Not Implemented |
OR0112 # 02 Y:1991 | 02 | 1991 | OPTIMIZE PLANT POWER FACTOR | $742 | $750 | Not Implemented |
OR0112 # 03 Y:1991 | 03 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $229 | $0 | Not Implemented |
OR0112 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $500 | $1,048 | Not Implemented |
OR0112 # 05 Y:1991 | 05 | 1991 | INSULATE BARE EQUIPMENT | $12,011 | $40,000 | Not Implemented |
OR0112 # 06 Y:1991 | 06 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $62 | $195 | Not Implemented |