Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

398

matching recommendations
Reset
SIC 242 Sawmills And Planing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0049 # 04 Y:1989 04 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $2,770 $3,720 Not Implemented
OR0049 # 05 Y:1989 05 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $132 $206 Implemented
OR0049 # 06 Y:1989 06 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $996 $2,000 Implemented
OR0038 # 01 Y:1988 01 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,528 $3,000 Implemented
OR0038 # 02 Y:1988 02 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $373 $350 Implemented
OR0038 # 03 Y:1988 03 1988 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,799 $3,021 Not Implemented
OR0038 # 04 Y:1988 04 1988 OPTIMIZE PLANT POWER FACTOR $3,067 $7,800 Implemented
OR0039 # 01 Y:1988 01 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,384 $5,000 Implemented
OR0039 # 02 Y:1988 02 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $498 $630 Implemented
OR0039 # 03 Y:1988 03 1988 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $73,000 $100,000 Not Implemented
OR0039 # 04 Y:1988 04 1988 OPTIMIZE PLANT POWER FACTOR $6,379 $13,650 Implemented
OR0039 # 05 Y:1988 05 1988 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $15,101 $32,576 Implemented
OR0018 # 01 Y:1988 01 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,235 $0 Implemented
OR0018 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $884 $761 Implemented
OR0018 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,068 $1,262 Implemented
OR0018 # 04 Y:1988 04 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,062 $1,074 Not Implemented
OR0018 # 05 Y:1988 05 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $434 $597 Implemented
OR0018 # 06 Y:1988 06 1988 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,000 $55,000 Not Implemented
OR0018 # 07 Y:1988 07 1988 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $7,785 $33,000 Not Implemented
OR0018 # 08 Y:1988 08 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,661 $10,500 Implemented
OR0009 # 01 Y:1987 01 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,979 $0 Not Implemented
OR0009 # 02 Y:1987 02 1987 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $13,372 $100 Not Implemented
OR0009 # 03 Y:1987 03 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,752 $500 Not Implemented
OR0009 # 04 Y:1987 04 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $23,307 $300 Not Implemented
OR0009 # 05 Y:1987 05 1987 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $6,734 $1,035 Not Implemented