Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
96
matching recommendationsSIC | 242 | Sawmills And Planing Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0744 # 01 Y:2018 | 01 | 2018 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $17,930 | $4,570 | Implemented |
AM0744 # 03 Y:2018 | 03 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,150 | $5,000 | Implemented |
AM0744 # 02 Y:2018 | 02 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,640 | $0 | Implemented |
AM0739 # 06 Y:2017 | 06 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,870 | $0 | Not Implemented |
AM0739 # 05 Y:2017 | 05 | 2017 | USE SYNTHETIC LUBRICANT | $2,400 | $0 | Implemented |
AM0739 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,820 | $9,600 | Implemented |
AM0739 # 03 Y:2017 | 03 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,430 | $0 | Implemented |
AM0739 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $17,900 | $28,900 | Not Implemented |
AM0739 # 01 Y:2017 | 01 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $44,300 | $31,800 | Implemented |
AM0739 # 07 Y:2017 | 07 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $730 | $300 | Implemented |
AM0739 # 08 Y:2017 | 08 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $540 | $300 | Implemented |
AM0538 # 05 Y:2008 | 05 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,200 | $0 | Not Implemented |
AM0538 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $1,045 | $0 | Not Implemented |
AM0538 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,770 | $1,120 | Implemented |
AM0538 # 04 Y:2008 | 04 | 2008 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $2,200,000 | $6,600,000 | Implemented |
AM0538 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,905 | $105,000 | Implemented |
AM0538 # 02 Y:2008 | 02 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $171,000 | $5,000 | Implemented |
AM0538 # 01 Y:2008 | 01 | 2008 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $192,300 | $174,034 | Not Implemented |
AM0495 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,250 | $200 | Implemented |
AM0495 # 09 Y:2005 | 09 | 2005 | USE SYNTHETIC LUBRICANT | $246 | $0 | Not Implemented |
AM0495 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,990 | $0 | Implemented |
AM0495 # 02 Y:2005 | 02 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,300 | $0 | Implemented |
AM0495 # 01 Y:2005 | 01 | 2005 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $138,400 | $50,960 | Not Implemented |
AM0495 # 08 Y:2005 | 08 | 2005 | USE PHOTOCELL CONTROLS | $280 | $33 | Implemented |
AM0495 # 07 Y:2005 | 07 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,200 | $3,750 | Implemented |