IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
SIC 2421 Sawmills And Planing Mills, General
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0646 # 02 Y:2020 02 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $225 $778 Not Implemented
NC0646 # 03 Y:2020 03 2020 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $188 $83 Not Implemented
NC0646 # 04 Y:2020 04 2020 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $694 $362 Implemented
NC0646 # 05 Y:2020 05 2020 OPTIMIZE PLANT POWER FACTOR $2,484 $7,500 Not Implemented
NC0646 # 06 Y:2020 06 2020 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $4,817 $6,709 Not Implemented
NC0646 # 01 Y:2020 01 2020 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $377,240 $300,000 Implemented
OD0105 # 01 Y:1998 01 1998 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $56,890 $175,200 Implemented
OD0105 # 02 Y:1998 02 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,837 $38,044 Implemented
OD0105 # 03 Y:1998 03 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,120 $5,907 Implemented
OD0105 # 04 Y:1998 04 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,362 $0 Not Implemented
OD0128 # 02 Y:1999 02 1999 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $854 $1,290 Not Implemented
OD0128 # 05 Y:1999 05 1999 $1,380 $1,155 Not Implemented
OD0128 # 04 Y:1999 04 1999 $26,400 $47,500 Not Implemented
OD0128 # 03 Y:1999 03 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $565 $420 Not Implemented
OD0128 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,386 $1,800 Not Implemented
TN0625 # 01 Y:1998 01 1998 $65,150 $545,645 Not Implemented
TN0625 # 02 Y:1998 02 1998 BURN WOOD BY-PRODUCTS FOR HEAT $237,780 $900,000 Not Implemented
TN0625 # 03 Y:1998 03 1998 IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) $60,120 $116,240 Implemented
TN0625 # 04 Y:1998 04 1998 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED $9,965 $5,000 Implemented
TN0625 # 05 Y:1998 05 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,380 $6,370 Implemented
TN0625 # 06 Y:1998 06 1998 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $900 $0 Implemented
TN0625 # 07 Y:1998 07 1998 INSTALL TIMERS AND/OR THERMOSTATS $210 $465 Not Implemented