Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
521
matching recommendationsSIC | 2426 | Hardwood Dimension & Flooring Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0063 # 07 Y:1995 | 07 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,746 | $0 | Implemented |
AR0063 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $876 | $300 | Implemented |
OR0240 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,950 | $7,729 | Implemented |
OR0240 # 02 Y:1995 | 02 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,925 | $57,725 | Not Implemented |
OR0240 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $410 | $0 | Not Implemented |
OR0240 # 04 Y:1995 | 04 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,795 | $99,195 | Implemented |
OR0240 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,308 | $15,000 | Implemented |
OR0240 # 06 Y:1995 | 06 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $2,403 | $500 | Not Implemented |
OR0240 # 07 Y:1995 | 07 | 1995 | OPTIMIZE PLANT POWER FACTOR | $16,062 | $20,000 | Not Implemented |
AR0057 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,500 | $438 | Implemented |
AR0057 # 02 Y:1995 | 02 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,881 | $17 | Implemented |
AR0057 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,188 | $8,450 | Implemented |
AR0057 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,333 | $0 | Implemented |
AR0057 # 05 Y:1995 | 05 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $54,784 | $6,000 | Not Implemented |
AR0057 # 06 Y:1995 | 06 | 1995 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $20,783 | $5,600 | Implemented |
AR0057 # 07 Y:1995 | 07 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $73,586 | $1,500 | Implemented |
AM0242 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,440 | $4,020 | Implemented |
AM0242 # 02 Y:1995 | 02 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $630 | $0 | Implemented |
AM0242 # 03 Y:1995 | 03 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $330 | $0 | Implemented |
AM0242 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $100 | $25 | Implemented |
AM0242 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $76 | $100 | Implemented |
TN0560 # 01 Y:1995 | 01 | 1995 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $354,456 | $1,091,000 | Not Implemented |
TN0560 # 02 Y:1995 | 02 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,066 | $0 | Implemented |
TN0560 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,912 | $9,700 | Not Implemented |
TN0560 # 04 Y:1995 | 04 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,384 | $0 | Not Implemented |