Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 2426 | Hardwood Dimension & Flooring Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0247 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,600 | $2,665 | Implemented |
NC0247 # 02 Y:2002 | 02 | 2002 | INSTALL SKYLIGHTS | $1,646 | $540 | Implemented |
NC0247 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,850 | $1,004 | Implemented |
NC0247 # 01 Y:2002 | 01 | 2002 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $44,473 | $120,000 | Implemented |
NC0247 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $427 | $100 | Implemented |
NC0247 # 09 Y:2002 | 09 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $860 | $500 | Implemented |
NC0247 # 05 Y:2002 | 05 | 2002 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $10,011 | $7,795 | Not Implemented |
NC0247 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $591 | $1,597 | Not Implemented |
NC0247 # 07 Y:2002 | 07 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $774 | $863 | Implemented |
NC0166 # 01 Y:1999 | 01 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $756 | $1,500 | Implemented |
NC0166 # 10 Y:1999 | 10 | 1999 | $7,700 | $1,000 | Implemented | |
NC0166 # 09 Y:1999 | 09 | 1999 | $14,000 | $15,500 | Implemented | |
NC0166 # 08 Y:1999 | 08 | 1999 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $29,365 | $82,000 | Not Implemented |
NC0166 # 07 Y:1999 | 07 | 1999 | BURN WOOD BY-PRODUCTS FOR HEAT | $12,902 | $62,200 | Not Implemented |
NC0166 # 06 Y:1999 | 06 | 1999 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $645 | $800 | Not Implemented |
NC0166 # 05 Y:1999 | 05 | 1999 | INSULATE FEEDWATER TANK | $328 | $340 | Implemented |
NC0166 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,328 | $5,000 | Not Implemented |
NC0166 # 03 Y:1999 | 03 | 1999 | USE PHOTOCELL CONTROLS | $601 | $150 | Implemented |
NC0166 # 02 Y:1999 | 02 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $5,877 | $15,000 | Not Implemented |
NC0126 # 12 Y:1997 | 12 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143 | $180 | Implemented |
NC0126 # 11 Y:1997 | 11 | 1997 | ADD AREA LIGHTING SWITCHES | $3,197 | $2,420 | Not Implemented |
NC0126 # 08 Y:1997 | 08 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $962 | $2,400 | Not Implemented |
NC0126 # 06 Y:1997 | 06 | 1997 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $33,895 | $56,800 | Not Implemented |
NC0126 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,042 | $5,200 | Implemented |
NC0126 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,564 | $12,000 | Not Implemented |