IAC logo
IAC Assessment: NC0247
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NC0247
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 2002
Principal Product Frames
NAICS n/a
SIC 2426 - Hardwood Dimension & Flooring Mills
Sales $5,000,000-$10,000,000
# of Employees 70
Plant Area (Sq.Ft.) 90,000
Annual Production 10,000 Thousand Feet
Production Hrs. Annual 4,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,729 1,498,800 kWh $0.06
Electricity Demand $30,909 4,755 kW-months/year $6.50
Electricity Fees $4,111 - $ -
TOTAL ENERGY COSTS $126,749
RECOMMENDED SAVINGS* $63,232 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $52,630
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS Savings:
$44,473
Cost:
$120,000
- - $16,068 4,755 $28,405 - -
-
kWh
$16,068
4,755
kW-months/year
$28,405
-
$
02: 2.7145 INSTALL SKYLIGHTS Savings:
$1,646
Cost:
$540
$1,646 26,980 - - - - $1,646
26,980
kWh
-
-
kW-months/year
-
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,600
Cost:
$2,665
$2,070 33,942 $530 81 - - $2,070
33,942
kWh
$530
81
kW-months/year
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$591
Cost:
$1,597
$364 5,966 $227 35 - - $364
5,966
kWh
$227
35
kW-months/year
-
-
$
05: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$10,011
Cost:
$7,795
$10,011 164,120 - - - - $10,011
164,120
kWh
-
-
kW-months/year
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$427
Cost:
$100
$324 5,304 $103 192 - - $324
5,304
kWh
$103
192
kW-months/year
-
-
$
07: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$774
Cost:
$863
$563 9,233 $211 32 - - $563
9,233
kWh
$211
32
kW-months/year
-
-
$
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,850
Cost:
$1,004
$1,402 22,982 $448 69 - - $1,402
22,982
kWh
$448
69
kW-months/year
-
-
$
09: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$860
Cost:
$500
$860 14,093 - - - - $860
14,093
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$63,232
Cost:
$135,064
$17,240 282,620 $17,587 5,164 $28,405 - $17,240
282,620
kWh
$17,587
5,164
kW-months/year
$28,405
-
$
TOTAL IMPLEMENTED Savings:
$52,630
Cost:
$125,672
$6,865 112,534 $17,360 5,129 $28,405 - $6,865
112,534
kWh
$17,360
5,129
kW-months/year
$28,405
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes