Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
118
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0198 # 07 Y:1998 | 07 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,809 | $14,150 | Not Implemented |
SD0198 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $259 | $916 | Implemented |
SD0198 # 09 Y:1998 | 09 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $178 | $180 | Not Implemented |
SD0198 # 10 Y:1998 | 10 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,600 | $8,500 | Implemented |
SD0198 # 11 Y:1998 | 11 | 1998 | MAKE A NEW BY-PRODUCT | $5,100 | $0 | Not Implemented |
SD0198 # 12 Y:1998 | 12 | 1998 | USE LESS WASTEFUL PACKAGING | $5,600 | $0 | Not Implemented |
SD0198 # 13 Y:1998 | 13 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,550 | $0 | Not Implemented |
SD0198 # 14 Y:1998 | 14 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,674 | $3,980 | Not Implemented |
SD0198 # 15 Y:1998 | 15 | 1998 | INCREASE USE OF AUTOMATION | $3,258 | $3,300 | Not Implemented |
SD0198 # 16 Y:1998 | 16 | 1998 | INCREASE USE OF AUTOMATION | $39,024 | $6,000 | Not Implemented |
NV0095 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,185 | $276 | Not Implemented |
NV0095 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $117 | $75 | Implemented |
NV0095 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,650 | $244 | Not Implemented |
NV0095 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $494 | $398 | Implemented |
NV0095 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,127 | $200 | Implemented |
NV0095 # 06 Y:1997 | 06 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,154 | $200 | Implemented |
NV0095 # 07 Y:1997 | 07 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $12,821 | $5,600 | Implemented |
NV0037 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,750 | $688 | Implemented |
NV0037 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $2,654 | $5,355 | Not Implemented |
NV0037 # 03 Y:1995 | 03 | 1995 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,969 | $275 | Implemented |
NV0037 # 04 Y:1995 | 04 | 1995 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,474 | $280 | Implemented |
NV0037 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $652 | $240 | Implemented |
NV0037 # 06 Y:1995 | 06 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $1,088 | $192 | Implemented |
NV0037 # 07 Y:1995 | 07 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,280 | $0 | Implemented |
NV0029 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,805 | $293 | Implemented |