Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,511
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0548 # 01 Y:2004 | 01 | 2004 | REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER | $16,080 | $1,150 | Implemented |
CO0548 # 02 Y:2004 | 02 | 2004 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $14,440 | $12,420 | Implemented |
CO0548 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,940 | $360 | Implemented |
CO0548 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,330 | $60 | Implemented |
CO0548 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $130 | $340 | Not Implemented |
CO0548 # 06 Y:2004 | 06 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $960 | $500 | Implemented |
CO0548 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $136 | $70 | Implemented |
OR0456 # 01 Y:2004 | 01 | 2004 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $-1,300 | $5,000 | Not Implemented |
OR0456 # 02 Y:2004 | 02 | 2004 | KEEP BOILER TUBES CLEAN | $37,240 | $1,760 | Not Implemented |
OR0456 # 03 Y:2004 | 03 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,900 | $2,410 | Not Implemented |
OR0456 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,900 | $12,600 | Not Implemented |
OR0456 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,550 | $15,400 | Implemented |
OR0453 # 01 Y:2004 | 01 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,340 | $150 | Not Implemented |
OR0453 # 02 Y:2004 | 02 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,100 | $2,950 | Not Implemented |
OR0453 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,680 | $6,920 | Not Implemented |
OR0453 # 04 Y:2004 | 04 | 2004 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $113,000 | $84,300 | Not Implemented |
OR0453 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,300 | $9,460 | Not Implemented |
OR0453 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,400 | $6,400 | Not Implemented |
OR0453 # 07 Y:2004 | 07 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $11,370 | $1,000 | Not Implemented |
OR0453 # 08 Y:2004 | 08 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,780 | $6,900 | Not Implemented |
OR0453 # 09 Y:2004 | 09 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,020 | $4,500 | Not Implemented |
NC0279 # 01 Y:2004 | 01 | 2004 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $3,220 | $20,000 | Implemented |
NC0279 # 02 Y:2004 | 02 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $25,415 | $25,000 | Not Implemented |
NC0279 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,096 | $1,875 | Implemented |
NC0279 # 04 Y:2004 | 04 | 2004 | $59,248 | $6,000 | Implemented |