Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,179

matching recommendations
Reset
SIC 2431 Millwork
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0417 # 06 Y:2012 06 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,063 $2,490 Not Implemented
SF0417 # 07 Y:2012 07 2012 INSTALL OCCUPANCY SENSORS $6,916 $31,417 Implemented
SF0417 # 08 Y:2012 08 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,407 $16,180 Implemented
OR0574 # 01 Y:2011 01 2011 INSTALL OCCUPANCY SENSORS $35,460 $21,200 Not Implemented
OR0574 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,450 $7,166 Implemented
OR0574 # 03 Y:2011 03 2011 REDUCE FLUID FLOW RATES $9,209 $15,000 Not Implemented
OR0574 # 04 Y:2011 04 2011 REDUCE FLUID FLOW RATES $13,265 $25,000 Not Implemented
OR0574 # 05 Y:2011 05 2011 REDUCE FLUID FLOW RATES $4,812 $18,000 Not Implemented
OR0574 # 06 Y:2011 06 2011 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $8,495 $18,038 Not Implemented
OR0574 # 07 Y:2011 07 2011 ADOPT IN-HOUSE MATERIAL GENERATION $228,949 $487,000 Not Implemented
MS0380 # 01 Y:2011 01 2011 REPAIR AND ELIMINATE STEAM LEAKS $19,820 $561 Not Implemented
MS0380 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $123,143 $194,049 Not Implemented
MS0380 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $81,959 $85,986 Not Implemented
MS0380 # 04 Y:2011 04 2011 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $8,239 $4,272 Not Implemented
MS0380 # 05 Y:2011 05 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $30,363 $7,080 Not Implemented
MS0380 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,944 $466 Not Implemented
WV0430 # 01 Y:2011 01 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $70,581 $20,000 Not Implemented
WV0430 # 02 Y:2011 02 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $43,659 $3,500 Implemented
WV0430 # 03 Y:2011 03 2011 USE RADIANT HEATER FOR SPOT HEATING $39,290 $65,840 Not Implemented
WV0430 # 04 Y:2011 04 2011 UPGRADE CONTROLS ON COMPRESSORS $34,733 $26,650 Implemented
WV0430 # 05 Y:2011 05 2011 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $28,475 $76,200 Not Implemented
WV0430 # 06 Y:2011 06 2011 OPTIMIZE PLANT POWER FACTOR $25,696 $37,805 Not Implemented
WV0430 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,692 $37,460 Implemented
WV0430 # 08 Y:2011 08 2011 COMBINE UTILITY METERS $10,426 $20,000 Not Implemented
WV0430 # 09 Y:2011 09 2011 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $8,265 $57,400 Not Implemented