Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0396 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,460 | $500 | Implemented |
AM0396 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $860 | $540 | Not Implemented |
AM0396 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $850 | $1,910 | Not Implemented |
AM0396 # 08 Y:2001 | 08 | 2001 | USE SYNTHETIC LUBRICANT | $390 | $0 | Not Implemented |
AM0396 # 09 Y:2001 | 09 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $280 | Not Implemented |
AM0390 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $51,050 | $162,000 | n/a |
AM0390 # 02 Y:2001 | 02 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $51,050 | $150,000 | Implemented |
AM0390 # 03 Y:2001 | 03 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $16,100 | $0 | Not Implemented |
AM0390 # 04 Y:2001 | 04 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $19,350 | $4,700 | Not Implemented |
AM0390 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,300 | $530 | Not Implemented |
AM0390 # 06 Y:2001 | 06 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $1,600 | $0 | Implemented |
AM0390 # 07 Y:2001 | 07 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,545 | $3,090 | Implemented |
AM0390 # 08 Y:2001 | 08 | 2001 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,100 | $780 | Not Implemented |
AM0390 # 09 Y:2001 | 09 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,100 | $200 | Implemented |
AM0390 # 10 Y:2001 | 10 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,080 | $50 | Implemented |
AM0390 # 11 Y:2001 | 11 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $960 | $20 | Not Implemented |
AM0390 # 12 Y:2001 | 12 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $680 | $0 | Implemented |
AM0254 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,390 | $2,000 | Implemented |
AM0254 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,840 | $0 | Implemented |
AM0254 # 03 Y:1995 | 03 | 1995 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,600 | $0 | Not Implemented |
AM0254 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $860 | $72 | Not Implemented |
AM0254 # 05 Y:1995 | 05 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $720 | $0 | Not Implemented |
AM0254 # 06 Y:1995 | 06 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $590 | $1,180 | Not Implemented |
AM0254 # 07 Y:1995 | 07 | 1995 | USE SYNTHETIC LUBRICANT | $220 | $0 | Not Implemented |
AM0254 # 08 Y:1995 | 08 | 1995 | USE PHOTOCELL CONTROLS | $130 | $40 | Implemented |