Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
138
matching recommendationsSIC | 2431 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0334 # 01 Y:1998 | 01 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $1,080,150 | $1,000,000 | Implemented |
OR0334 # 02 Y:1998 | 02 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $14,550 | $31,520 | Implemented |
OR0334 # 03 Y:1998 | 03 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $48,900 | $220,000 | Not Implemented |
OR0334 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $15,977 | $44,400 | Not Implemented |
OR0334 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,499 | $6,000 | Implemented |
OR0334 # 06 Y:1998 | 06 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $14,409 | $9,600 | Implemented |
OR0334 # 07 Y:1998 | 07 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,890 | $0 | Implemented |
OR0334 # 08 Y:1998 | 08 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,250 | $0 | Implemented |
OR0334 # 09 Y:1998 | 09 | 1998 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $1,146 | $350 | Not Implemented |
OR0199 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,311 | $3,000 | Implemented |
OR0199 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $256 | $1,029 | Implemented |
OR0199 # 03 Y:1994 | 03 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,465 | $0 | Implemented |
OR0199 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $433 | $1,820 | Implemented |
OR0199 # 05 Y:1994 | 05 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $385 | $500 | Implemented |
OR0199 # 06 Y:1994 | 06 | 1994 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $953 | $39,794 | Implemented |
OR0128 # 01 Y:1991 | 01 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,899 | $0 | Implemented |
OR0128 # 02 Y:1991 | 02 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $758 | $0 | Implemented |
OR0128 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $651 | $0 | Implemented |
OR0128 # 04 Y:1991 | 04 | 1991 | RECOVER MECHANICAL ENERGY | $15,535 | $4,270 | Implemented |
OR0128 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $545 | $0 | Implemented |
OR0128 # 06 Y:1991 | 06 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $571 | $1,000 | Implemented |
OR0128 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $88 | $189 | Implemented |
OR0128 # 08 Y:1991 | 08 | 1991 | OPTIMIZE PLANT POWER FACTOR | $308 | $750 | Implemented |
OR0119 # 01 Y:1991 | 01 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $30,780 | $600 | Not Implemented |
OR0119 # 02 Y:1991 | 02 | 1991 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,126 | $2,580 | Not Implemented |