Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
103
matching recommendationsSIC | 2435 | Hardwood Veneer And Plywood |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0573 # 05 Y:2011 | 05 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,543 | $7,806 | Implemented |
OR0573 # 06 Y:2011 | 06 | 2011 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $71,712 | $65,575 | Not Implemented |
OR0573 # 07 Y:2011 | 07 | 2011 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $987 | $4,800 | Not Implemented |
OR0564 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $7,248 | $31,290 | Not Implemented |
OR0564 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM THICKNESS INSULATION | $64,658 | $105,222 | Implemented |
OR0564 # 04 Y:2010 | 04 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,849 | $7,575 | Not Implemented |
OR0564 # 03 Y:2010 | 03 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $9,666 | $40,000 | Not Implemented |
OR0564 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,314 | $31,314 | Implemented |
OR0564 # 01 Y:2010 | 01 | 2010 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $11,375 | $32,340 | Not Implemented |
OR0555 # 04 Y:2010 | 04 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $1 | Implemented |
OR0555 # 03 Y:2010 | 03 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,978 | $11,900 | Implemented |
OR0555 # 02 Y:2010 | 02 | 2010 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $32,115 | $37,100 | Not Implemented |
OR0555 # 01 Y:2010 | 01 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $257,883 | $405,450 | Not Implemented |
OR0548 # 08 Y:2009 | 08 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,500 | $600 | Implemented |
OR0548 # 07 Y:2009 | 07 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $7,349 | $0 | Implemented |
OR0548 # 06 Y:2009 | 06 | 2009 | ADD AREA LIGHTING SWITCHES | $8,092 | $1,600 | Not Implemented |
OR0548 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,882 | $9,900 | Implemented |
OR0548 # 04 Y:2009 | 04 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15,295 | $0 | Implemented |
OR0548 # 03 Y:2009 | 03 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $21,000 | $8,800 | Not Implemented |
OR0548 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $47,605 | $128,300 | Implemented |
OR0548 # 01 Y:2009 | 01 | 2009 | KEEP SOLID FUELS / RAW MATERIALS DRY | $294,300 | $290,000 | Not Implemented |
OR0468 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,700 | $13,800 | Implemented |
OR0468 # 09 Y:2004 | 09 | 2004 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $14,800 | $15,700 | Implemented |
OR0468 # 10 Y:2004 | 10 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,800 | $26,600 | Implemented |
OR0468 # 11 Y:2004 | 11 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,650 | $24,900 | Not Implemented |