Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
374
matching recommendationsSIC | 2435 | Hardwood Veneer And Plywood |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0573 # 03 Y:2011 | 03 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,064 | $7,045 | Not Implemented |
OR0573 # 02 Y:2011 | 02 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $18,705 | $7,045 | Not Implemented |
OR0573 # 01 Y:2011 | 01 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,057 | $18,500 | Not Implemented |
OR0564 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $7,248 | $31,290 | Not Implemented |
OR0564 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM THICKNESS INSULATION | $64,658 | $105,222 | Implemented |
OR0564 # 04 Y:2010 | 04 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,849 | $7,575 | Not Implemented |
OR0564 # 03 Y:2010 | 03 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $9,666 | $40,000 | Not Implemented |
OR0564 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,314 | $31,314 | Implemented |
OR0564 # 01 Y:2010 | 01 | 2010 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $11,375 | $32,340 | Not Implemented |
OR0555 # 04 Y:2010 | 04 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $1 | Implemented |
OR0555 # 03 Y:2010 | 03 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,978 | $11,900 | Implemented |
OR0555 # 01 Y:2010 | 01 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $257,883 | $405,450 | Not Implemented |
OR0555 # 02 Y:2010 | 02 | 2010 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $32,115 | $37,100 | Not Implemented |
WV0399 # 13 Y:2010 | 13 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,498 | $4,153 | Not Implemented |
WV0399 # 12 Y:2010 | 12 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,246 | $26 | Not Implemented |
WV0399 # 02 Y:2010 | 02 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $154,014 | $106,000 | Not Implemented |
WV0399 # 01 Y:2010 | 01 | 2010 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $215,411 | $540,000 | Not Implemented |
WV0399 # 03 Y:2010 | 03 | 2010 | COVER OPEN TANKS | $83,144 | $7,290 | Implemented |
WV0399 # 04 Y:2010 | 04 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $37,930 | $39,900 | Implemented |
WV0399 # 05 Y:2010 | 05 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $18,121 | $1,644 | Implemented |
WV0399 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,812 | $0 | Implemented |
WV0399 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,889 | $0 | Implemented |
WV0399 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,515 | $1,717 | Implemented |
WV0399 # 09 Y:2010 | 09 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,930 | $1,000 | Implemented |
WV0399 # 10 Y:2010 | 10 | 2010 | INSULATE BARE EQUIPMENT | $2,955 | $3,544 | Implemented |