Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
170
matching recommendationsSIC | 2439 | Structural Wood Members, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0582 # 04 Y:2012 | 04 | 2012 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $14,435 | $34,000 | Not Implemented |
OR0582 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,291 | $23,135 | Not Implemented |
OR0582 # 02 Y:2012 | 02 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $25,857 | $33,400 | Not Implemented |
OR0582 # 01 Y:2012 | 01 | 2012 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $720 | $500 | Not Implemented |
OR0554 # 01 Y:2010 | 01 | 2010 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $33,705 | $0 | Implemented |
OR0554 # 02 Y:2010 | 02 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,667 | $700 | Not Implemented |
OR0554 # 05 Y:2010 | 05 | 2010 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $6,200 | $1,900 | Not Implemented |
OR0554 # 04 Y:2010 | 04 | 2010 | REDUCE FLUID FLOW RATES | $6,442 | $6,442 | Implemented |
OR0554 # 03 Y:2010 | 03 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $13,900 | $1,500 | Implemented |
LL0318 # 07 Y:2009 | 07 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $67 | $156 | Implemented |
LL0318 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $818 | $525 | Implemented |
LL0318 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,541 | $894 | Not Implemented |
LL0318 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,138 | $27,225 | Not Implemented |
LL0318 # 03 Y:2009 | 03 | 2009 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,250 | $1,410 | Implemented |
LL0318 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,944 | $8,910 | Implemented |
LL0318 # 01 Y:2009 | 01 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $208,490 | $16,797 | Implemented |
BD0337 # 02 Y:2007 | 02 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,425 | $480 | Implemented |
BD0337 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $927 | $1,115 | Not Implemented |
BD0337 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $926 | $2 | Not Implemented |
BD0337 # 04 Y:2007 | 04 | 2007 | USE SYNTHETIC LUBRICANT | $228 | $601 | Not Implemented |
BD0337 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,084 | $2,150 | Not Implemented |
OR0516 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,400 | $9,800 | Implemented |
OR0516 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,600 | $15,300 | Implemented |
OR0516 # 01 Y:2007 | 01 | 2007 | OPTIMIZE FILTRATION CLEANING / REPLACEMENT TO MINIMIZE AIR RESISTANCE | $5,800 | $0 | Not Implemented |
OR0516 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $5,300 | $7,800 | Implemented |