Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
508
matching recommendationsSIC | 245 | Wood Buildings And Mobile Homes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0170 # 09 Y:1997 | 09 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,438 | $25 | Not Implemented |
UF0170 # 10 Y:1997 | 10 | 1997 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $5,666 | $0 | Not Implemented |
UF0170 # 11 Y:1997 | 11 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $18,237 | $3,120 | Implemented |
UF0170 # 12 Y:1997 | 12 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $32,000 | $50,000 | Implemented |
OR0287 # 01 Y:1997 | 01 | 1997 | REVISE RAW MATERIAL SPECS | $32,300 | $104,000 | Not Implemented |
OR0287 # 02 Y:1997 | 02 | 1997 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $17,270 | $0 | Not Implemented |
OR0287 # 03 Y:1997 | 03 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $480 | $0 | Implemented |
OR0287 # 04 Y:1997 | 04 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $260 | $0 | Not Implemented |
OR0287 # 05 Y:1997 | 05 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,770 | $2,885 | Implemented |
OR0287 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $0 | $2,000 | Implemented |
OR0287 # 07 Y:1997 | 07 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $450 | $2,000 | Not Implemented |
OR0287 # 08 Y:1997 | 08 | 1997 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $9,460 | $134,000 | Not Implemented |
ND0262 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $217 | $450 | Implemented |
ND0262 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $391 | $200 | Implemented |
ND0262 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,763 | $400 | Implemented |
ND0262 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,676 | $3,770 | Implemented |
ND0262 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $598 | $537 | Implemented |
ND0262 # 06 Y:1996 | 06 | 1996 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $251 | $475 | Not Implemented |
ND0261 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,345 | $400 | Implemented |
ND0261 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $204 | $200 | Not Implemented |
ND0261 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $167 | $315 | Implemented |
ND0261 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $207 | $100 | Not Implemented |
ND0261 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $141 | Not Implemented |
ND0261 # 06 Y:1996 | 06 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $372 | $720 | Not Implemented |
ND0261 # 07 Y:1996 | 07 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,020 | $480 | Implemented |