Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1997 |
Principal Product | Mobile Homes |
NAICS | n/a |
SIC | 2451 - Mobile Homes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 1,336 Pieces |
Production Hrs. Annual | 3,300 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $77,037 | 1,479,484 | kWh | $0.05 |
Electricity Demand | $49,374 | 5,720 | kW-months/year | $8.63 |
TOTAL ENERGY COSTS | $130,611 | |||
RECOMMENDED SAVINGS* | $102,309 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $71,524 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,266 Cost: $620 |
$791 | 15,240 | $475 | 55 | - | - | - | - | - | - | - | - | - | - |
$791 15,240 kWh |
$475 55 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $481 Cost: $882 |
$270 | 5,275 | $211 | 24 | - | - | - | - | - | - | - | - | - | - |
$270 5,275 kWh |
$211 24 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $2,872 Cost: $1,507 |
$1,943 | 37,222 | $929 | 108 | - | - | - | - | - | - | - | - | - | - |
$1,943 37,222 kWh |
$929 108 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,735 Cost: $1,550 |
$4,735 | 92,907 | - | - | - | - | - | - | - | - | - | - | - | - |
$4,735 92,907 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $5,054 Cost: - |
- | - | $5,054 | 586 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$5,054 586 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $640 Cost: $894 |
- | - | - | - | - | - | - | - | - | - | $640 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
$640 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $6,879 Cost: $18,400 |
- | - | - | - | $4,200 | 113,400 | - | - | - | - | - | - | $2,679 | - |
- - kWh |
- - kW-months/year |
$4,200 113,400 lb |
- - $ |
- - $ |
- - $ |
$2,679 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $21,041 Cost: $5,500 |
$(-262) | (-4,982) | - | - | - | - | $(-9,945) | - | - | - | $31,248 | - | - | - |
$(-262) (-4,982) kWh |
- - kW-months/year |
- - lb |
$(-9,945) - $ |
- - $ |
$31,248 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $3,438 Cost: $25 |
- | - | - | - | - | - | - | - | $3,438 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$3,438 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $5,666 Cost: - |
- | - | - | - | - | - | $5,666 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$5,666 - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $18,237 Cost: $3,120 |
- | - | - | - | - | - | $13,600 | - | - | - | $4,637 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$13,600 - $ |
- - $ |
$4,637 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $32,000 Cost: $50,000 |
- | - | - | - | - | - | $32,000 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$32,000 - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $102,309 Cost: $82,498 |
$7,477 | 145,662 | $6,669 | 773 | $4,200 | 113,400 | $41,321 | - | $3,438 | - | $36,525 | - | $2,679 | - | $7,477 145,662 kWh |
$6,669 773 kW-months/year |
$4,200 113,400 lb |
$41,321 - $ |
$3,438 - $ |
$36,525 - $ |
$2,679 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $71,524 Cost: $76,079 |
$7,739 | 150,644 | $6,669 | 773 | $4,200 | 113,400 | $45,600 | - | - | - | $4,637 | - | $2,679 | - | $7,739 150,644 kWh |
$6,669 773 kW-months/year |
$4,200 113,400 lb |
$45,600 - $ |
- - $ |
$4,637 - $ |
$2,679 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production |