Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,425
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0338 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $2,166 | $1,050 | Implemented |
LE0338 # 11 Y:2012 | 11 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $2,293 | $100 | Implemented |
LE0338 # 12 Y:2012 | 12 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,635 | $8,000 | Implemented |
LE0338 # 13 Y:2012 | 13 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,134 | $200 | Implemented |
LE0338 # 14 Y:2012 | 14 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $330 | $103 | Implemented |
NC0442 # 01 Y:2012 | 01 | 2012 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,357 | $35,000 | Not Implemented |
NC0442 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $44,787 | $200,000 | Not Implemented |
NC0442 # 03 Y:2012 | 03 | 2012 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $4,788 | $20,000 | Not Implemented |
NC0442 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,196 | $4,425 | Implemented |
NC0442 # 05 Y:2012 | 05 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $3,045 | $6,067 | Implemented |
NC0442 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,418 | $9,330 | Implemented |
NC0442 # 07 Y:2012 | 07 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $977 | $231 | Implemented |
NC0442 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,227 | $300 | Implemented |
WV0444 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,498 | $8,040 | Not Implemented |
WV0444 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,137 | $15,286 | Implemented |
WV0444 # 03 Y:2012 | 03 | 2012 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,848 | $1,560 | Not Implemented |
WV0444 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,825 | $4,714 | Implemented |
WV0444 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,676 | $10,532 | Implemented |
WV0444 # 06 Y:2012 | 06 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,945 | $1,000 | Not Implemented |
WV0444 # 07 Y:2012 | 07 | 2012 | IMPROVE LUBRICATION PRACTICES | $1,688 | $500 | Implemented |
WV0444 # 08 Y:2012 | 08 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,593 | $1,555 | Not Implemented |
WV0444 # 09 Y:2012 | 09 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,548 | $0 | Implemented |
WV0444 # 10 Y:2012 | 10 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,353 | $838 | Implemented |
WV0444 # 11 Y:2012 | 11 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $247 | $290 | Not Implemented |
TT0084 # 01 Y:2012 | 01 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,296 | $6,000 | Not Implemented |