Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,398

matching recommendations
Reset
SIC 249 Miscellaneous Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0064 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $245 $139 Implemented
OR0064 # 05 Y:1989 05 1989 OPTIMIZE PLANT POWER FACTOR $1,704 $975 Implemented
OR0055 # 01 Y:1989 01 1989 INSULATE BARE EQUIPMENT $1,145 $443 Implemented
OR0055 # 02 Y:1989 02 1989 INSULATE BARE EQUIPMENT $1,169 $553 Implemented
OR0055 # 03 Y:1989 03 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,773 $1,200 Not Implemented
OR0055 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $439 $425 Implemented
OR0055 # 05 Y:1989 05 1989 RECOVER WASTE HEAT FROM EQUIPMENT $4,067 $947 Implemented
OR0055 # 06 Y:1989 06 1989 OPTIMIZE PLANT POWER FACTOR $3,950 $8,400 Implemented
OR0055 # 07 Y:1989 07 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $333 $1,000 Not Implemented
MA0136 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $422 $892 Implemented
MA0136 # 02 Y:1989 02 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,244 $480 Not Implemented
MA0136 # 03 Y:1989 03 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,017 $1,400 Implemented
MA0136 # 04 Y:1989 04 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $372 $200 Not Implemented
MA0136 # 05 Y:1989 05 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $2,595 $3,602 Not Implemented
GT0364 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $74 $150 Implemented
GT0364 # 02 Y:1988 02 1988 IMPROVE LUBRICATION PRACTICES $2,630 $0 Implemented
GT0364 # 03 Y:1988 03 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,433 $0 Implemented
GT0364 # 04 Y:1988 04 1988 REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT $19,102 $28,000 Not Implemented
LT0131 # 01 Y:1988 01 1988 RECOVER WASTE HEAT FROM EQUIPMENT $800 $2,400 Implemented
LT0131 # 02 Y:1988 02 1988 REDESIGN PROCESS $21,900 $20,130 Not Implemented
LT0131 # 03 Y:1988 03 1988 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $930 $1,760 Implemented
LT0131 # 04 Y:1988 04 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $138 $362 Implemented
LT0131 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $284 $0 Implemented
LT0131 # 06 Y:1988 06 1988 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $860 $100 Implemented
LT0131 # 08 Y:1988 08 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $85 $0 Implemented