Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
359
matching recommendationsSIC | 2491 | Wood Preserving |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0487 # 06 Y:1993 | 06 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,980 | $0 | Not Implemented |
OR0139 # 01 Y:1992 | 01 | 1992 | INSTALL SET-BACK TIMERS | $633 | $0 | Implemented |
OR0139 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $291 | $0 | Implemented |
OR0139 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,876 | $1,000 | Implemented |
OR0139 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,685 | $10,000 | Implemented |
OR0139 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $218 | $4,614 | Implemented |
OR0139 # 06 Y:1992 | 06 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,355 | $61,690 | Not Implemented |
OR0109 # 01 Y:1991 | 01 | 1991 | INSULATE BARE EQUIPMENT | $1,432 | $1,506 | Not Implemented |
OR0109 # 02 Y:1991 | 02 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,381 | $1,831 | Not Implemented |
OR0109 # 03 Y:1991 | 03 | 1991 | OPTIMIZE PLANT POWER FACTOR | $2,806 | $3,900 | Not Implemented |
OR0109 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $165 | $331 | Not Implemented |
OK0309 # 01 Y:1990 | 01 | 1990 | BURN WOOD BY-PRODUCTS FOR HEAT | $12,631 | $17,000 | Not Implemented |
OK0309 # 02 Y:1990 | 02 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $114 | $221 | Implemented |
OK0309 # 03 Y:1990 | 03 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $357 | $0 | Implemented |
OK0309 # 04 Y:1990 | 04 | 1990 | IMPROVE LUBRICATION PRACTICES | $1,235 | $0 | Implemented |
OK0309 # 05 Y:1990 | 05 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $262 | $579 | Implemented |
AM0091 # 01 Y:1990 | 01 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,075 | $50,000 | Not Implemented |
AM0091 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,720 | $1,100 | Implemented |
AM0091 # 03 Y:1990 | 03 | 1990 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,500 | $0 | Not Implemented |
AM0091 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $4,080 | $16,400 | Implemented |
AM0091 # 05 Y:1990 | 05 | 1990 | REDUCE EXCESS STEAM BLEEDING | $3,575 | $3,750 | Not Implemented |
AM0091 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,030 | $0 | Not Implemented |
AM0091 # 07 Y:1990 | 07 | 1990 | OPTIMIZE PLANT POWER FACTOR | $1,800 | $3,500 | Implemented |
AM0091 # 08 Y:1990 | 08 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $1,600 | $2,400 | Implemented |
AM0091 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $1,600 | $0 | Not Implemented |