Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsSIC | 2493 | Reconstituted Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0575 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $4,280 | $2,630 | Not Implemented |
OR0575 # 06 Y:2011 | 06 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $3,994 | $16,460 | Not Implemented |
OR0575 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,400 | $7,692 | Not Implemented |
OR0575 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,389 | $948 | Implemented |
OR0575 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,748 | $3,023 | Implemented |
OR0575 # 02 Y:2011 | 02 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $7,781 | $500 | Not Implemented |
OR0575 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,800 | $0 | Not Implemented |
NC0427 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $5,500 | $150 | Not Implemented |
NC0427 # 12 Y:2011 | 12 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $126,880 | $500,000 | Not Implemented |
NC0427 # 11 Y:2011 | 11 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $1,050 | Not Implemented |
NC0427 # 01 Y:2011 | 01 | 2011 | BURN A LESS EXPENSIVE GRADE OF FUEL | $155,882 | $10,000 | Implemented |
NC0427 # 09 Y:2011 | 09 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $106,205 | $1,200 | Implemented |
NC0427 # 08 Y:2011 | 08 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,000 | $600 | Implemented |
NC0427 # 07 Y:2011 | 07 | 2011 | INSULATE FEEDWATER TANK | $3,200 | $1,200 | Implemented |
NC0427 # 06 Y:2011 | 06 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,000 | $200 | Implemented |
NC0427 # 05 Y:2011 | 05 | 2011 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $178,345 | $50,000 | Implemented |
NC0427 # 04 Y:2011 | 04 | 2011 | KEEP BOILER TUBES CLEAN | $104,205 | $18,000 | Implemented |
NC0427 # 03 Y:2011 | 03 | 2011 | KEEP BOILER TUBES CLEAN | $164,666 | $20,000 | Implemented |
NC0427 # 02 Y:2011 | 02 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $209,278 | $1,200 | Not Implemented |