Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
468
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0327 # 10 Y:2005 | 10 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $651 | $1,251 | Implemented |
NC0324 # 01 Y:2005 | 01 | 2005 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $4,040 | $500 | Implemented |
NC0324 # 02 Y:2005 | 02 | 2005 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $524 | $500 | Not Implemented |
NC0324 # 03 Y:2005 | 03 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $413 | $2,000 | Not Implemented |
NC0324 # 04 Y:2005 | 04 | 2005 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $1,571 | $5,425 | Not Implemented |
NC0324 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,365 | $3,749 | Not Implemented |
NC0324 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,020 | $1,991 | Implemented |
NC0311 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,798 | $14,107 | Implemented |
NC0311 # 02 Y:2005 | 02 | 2005 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $15,075 | $4,000 | Not Implemented |
NC0311 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,158 | $100 | Implemented |
NC0311 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $23,954 | $750 | Implemented |
NC0311 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,051 | $7,280 | Not Implemented |
NC0311 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,142 | $3,555 | Implemented |
NC0311 # 07 Y:2005 | 07 | 2005 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $242,500 | $150,000 | Not Implemented |
NC0311 # 08 Y:2005 | 08 | 2005 | INSTALL SYSTEM TO COLLECT SCRAP | $6,250 | $10,000 | Implemented |
NC0240 # 01 Y:2002 | 01 | 2002 | KEEP BOILER TUBES CLEAN | $12,204 | $10,000 | Implemented |
NC0240 # 02 Y:2002 | 02 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $673 | $1,146 | Implemented |
NC0240 # 03 Y:2002 | 03 | 2002 | USE PHOTOCELL CONTROLS | $118 | $200 | Implemented |
NC0240 # 04 Y:2002 | 04 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $132 | $60 | Implemented |
NC0240 # 05 Y:2002 | 05 | 2002 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $3,000 | $1,000 | Implemented |
NC0240 # 06 Y:2002 | 06 | 2002 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $100,000 | $200,000 | Implemented |
NC0239 # 01 Y:2002 | 01 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,731 | $15,000 | Not Implemented |
NC0239 # 02 Y:2002 | 02 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $614 | $3,190 | Implemented |
NC0239 # 03 Y:2002 | 03 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $132 | $60 | Implemented |
NC0239 # 04 Y:2002 | 04 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,119 | $15,000 | Not Implemented |