Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,564
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0068 # 07 Y:1995 | 07 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,680 | $62,972 | Implemented |
SF0068 # 08 Y:1995 | 08 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,266 | $7,015 | Implemented |
SF0068 # 09 Y:1995 | 09 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,731 | $6,605 | Implemented |
SF0068 # 10 Y:1995 | 10 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,393 | $700 | Implemented |
SF0068 # 11 Y:1995 | 11 | 1995 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $6,972 | $9,060 | Implemented |
SF0068 # 12 Y:1995 | 12 | 1995 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $3,888 | $14,750 | Implemented |
MS0035 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $817 | $50 | Implemented |
MS0035 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $5,164 | $2,130 | Implemented |
MS0035 # 03 Y:1995 | 03 | 1995 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $11,921 | $12,146 | Not Implemented |
MS0035 # 04 Y:1995 | 04 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $678 | $20 | Not Implemented |
MS0035 # 05 Y:1995 | 05 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $2,158 | $5,000 | Not Implemented |
MS0035 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,824 | $4,949 | Not Implemented |
MS0035 # 07 Y:1995 | 07 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,198 | $32,850 | Not Implemented |
TN0553 # 01 Y:1995 | 01 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $810 | $0 | Implemented |
TN0553 # 02 Y:1995 | 02 | 1995 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,313 | $1,320 | Implemented |
TN0553 # 03 Y:1995 | 03 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $853 | $0 | Implemented |
TN0553 # 04 Y:1995 | 04 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,284 | $20,800 | Not Implemented |
MS0032 # 01 Y:1995 | 01 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $973 | $75 | Implemented |
MS0032 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,838 | $11,514 | Not Implemented |
MS0032 # 03 Y:1995 | 03 | 1995 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $2,758 | $5,700 | Not Implemented |
MS0032 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $674 | $1,800 | Not Implemented |
MS0032 # 05 Y:1995 | 05 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $1,583 | $20 | Implemented |
CO0334 # 01 Y:1995 | 01 | 1995 | CONVERT TO ELECTROSTATIC POWDER COATING | $91,310 | $150,000 | Implemented |
CO0334 # 02 Y:1995 | 02 | 1995 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $39,490 | $50,000 | Implemented |
CO0334 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,340 | $16,770 | Implemented |