Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
468
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0239 # 05 Y:2002 | 05 | 2002 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $11,025 | $6,500 | Not Implemented |
NC0233 # 01 Y:2002 | 01 | 2002 | BURN WOOD BY-PRODUCTS FOR HEAT | $55,321 | $109,000 | n/a |
NC0233 # 02 Y:2002 | 02 | 2002 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,359 | $2,000 | Implemented |
NC0233 # 03 Y:2002 | 03 | 2002 | IMPROVE SPACE COMFORT CONDITIONING | $75,150 | $10,000 | Implemented |
NC0233 # 04 Y:2002 | 04 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $293 | $778 | Implemented |
NC0233 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $186 | $289 | Not Implemented |
NC0227 # 01 Y:2001 | 01 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,391 | $250 | Not Implemented |
NC0227 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,815 | $30,000 | Not Implemented |
NC0227 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $662 | $308 | Not Implemented |
NC0227 # 04 Y:2001 | 04 | 2001 | IMPROVE COMBUSTION CONTROL CAPABILITY | $89,586 | $60,000 | Not Implemented |
NC0227 # 05 Y:2001 | 05 | 2001 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $30,612 | $50,000 | Not Implemented |
NC0227 # 06 Y:2001 | 06 | 2001 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $200,000 | $35,000 | Not Implemented |
NC0227 # 07 Y:2001 | 07 | 2001 | CONTROL PRESSURE ON STEAMER OPERATIONS | $7,356 | $7,500 | Implemented |
NC0227 # 08 Y:2001 | 08 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,500 | $5,000 | Not Implemented |
NC0227 # 09 Y:2001 | 09 | 2001 | ADJUST BURNERS FOR EFFICIENT OPERATION | $17,577 | $15,000 | Not Implemented |
NC0227 # 10 Y:2001 | 10 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,636 | $4,205 | Implemented |
NC0227 # 11 Y:2001 | 11 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,277 | $2,690 | Not Implemented |
NC0227 # 12 Y:2001 | 12 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $824 | $1,210 | Implemented |
NC0227 # 13 Y:2001 | 13 | 2001 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $8,933 | $10,067 | Implemented |
NC0227 # 14 Y:2001 | 14 | 2001 | CONDENSE OPERATION INTO ONE BUILDING | $279,320 | $500,000 | Implemented |
NC0227 # 15 Y:2001 | 15 | 2001 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $23,716 | $15,000 | Not Implemented |
NC0188 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $600 | $440 | Implemented |
NC0188 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $1,623 | Not Implemented |
NC0188 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,067 | $6,800 | Not Implemented |
NC0188 # 04 Y:2000 | 04 | 2000 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $2,795 | $1,500 | Not Implemented |