Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,525

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0446 # 08 Y:2012 08 2012 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,979 $8,800 Not Implemented
NC0446 # 09 Y:2012 09 2012 INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION $28,690 $71,725 Not Implemented
NC0441 # 01 Y:2012 01 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,551 $44,599 Implemented
NC0441 # 02 Y:2012 02 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $875 $0 Implemented
NC0441 # 03 Y:2012 03 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $161 $100 Implemented
NC0441 # 04 Y:2012 04 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $782 $300 Not Implemented
NC0441 # 05 Y:2012 05 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $9,319 $1,000 Not Implemented
NC0441 # 06 Y:2012 06 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $4,151 $1,000 Not Implemented
NC0441 # 07 Y:2012 07 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $350 $800 Implemented
NC0441 # 08 Y:2012 08 2012 INCREASE AMOUNT OF CONDENSATE RETURNED $462 $600 Implemented
NC0441 # 09 Y:2012 09 2012 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $1,800 $1,000 Not Implemented
NC0441 # 10 Y:2012 10 2012 REPAIR OR REPLACE STEAM TRAPS $1,119 $1,000 Implemented
NC0441 # 11 Y:2012 11 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,596 $4,760 Implemented
NC0441 # 12 Y:2012 12 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $551 $7,310 Implemented
NC0441 # 13 Y:2012 13 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $659 $5,880 Implemented
NC0441 # 14 Y:2012 14 2012 DEVELOP A REPAIR/REPLACE POLICY $500 $1,980 Implemented
NC0441 # 15 Y:2012 15 2012 USE HEAT PUMP FOR SPACE CONDITIONING $1,795 $10,400 Not Implemented
MS0383 # 01 Y:2011 01 2011 RECOVER WASTE HEAT FROM EQUIPMENT $7,135 $6,411 Not Implemented
MS0383 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,874 $139,671 Implemented
MS0383 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,458 $26,246 Implemented
MS0383 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,247 $33,997 Implemented
MS0383 # 05 Y:2011 05 2011 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,584 $659 Not Implemented
MS0383 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $757 $281 Implemented
LE0324 # 01 Y:2011 01 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,284 $122,400 Not Implemented
LE0324 # 02 Y:2011 02 2011 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,133 $5,085 Not Implemented