IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

148

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0263 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,300 $58,035 Not Implemented
BD0263 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,939 $2,400 Implemented
BD0263 # 03 Y:2004 03 2004 USE RADIANT HEATER FOR SPOT HEATING $9,868 $20,520 Not Implemented
BD0263 # 04 Y:2004 04 2004 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $9,390 $20,020 Not Implemented
BD0263 # 05 Y:2004 05 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,226 $3,114 Not Implemented
BD0263 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,501 $750 Not Implemented
BD0263 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $1,654 $1,575 Not Implemented
BD0263 # 08 Y:2004 08 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,537 $4,000 Not Implemented
BD0263 # 09 Y:2004 09 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $691 $1,050 Implemented
BD0263 # 10 Y:2004 10 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $421 $377 Implemented
BD0263 # 11 Y:2004 11 2004 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $26,600 $130 Implemented
BD0263 # 12 Y:2004 12 2004 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,120 $260 Not Implemented
IC0030 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,316 $1,400 Implemented
IC0030 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,674 $27,188 Implemented
IC0030 # 03 Y:2002 03 2002 INSTALL OCCUPANCY SENSORS $2,438 $1,225 Not Implemented
IC0030 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,602 $25,370 Implemented
IC0030 # 05 Y:2002 05 2002 MODIFY WORKLOAD $132,950 $36,600 Implemented
IC0030 # 06 Y:2002 06 2002 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $9,840 $250 Not Implemented
WI0289 # 01 Y:1997 01 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $17,900 $0 Implemented
WI0289 # 02 Y:1997 02 1997 ADOPT IN-HOUSE MATERIAL GENERATION $12,690 $0 Implemented
WI0289 # 03 Y:1997 03 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,496 $11,150 Not Implemented
WI0289 # 04 Y:1997 04 1997 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,349 $22,000 Not Implemented
WI0289 # 05 Y:1997 05 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $6,780 $34,425 Not Implemented
WI0289 # 06 Y:1997 06 1997 DISTILL CONTAMINATED SOLVENTS FOR REUSE $1,430 $0 Implemented
WI0289 # 07 Y:1997 07 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,219 $150 Implemented