Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

169

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0068 # 08 Y:1995 08 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,266 $7,015 Implemented
SF0068 # 07 Y:1995 07 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $35,680 $62,972 Implemented
SF0068 # 06 Y:1995 06 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,141 $1,587 Implemented
SF0068 # 05 Y:1995 05 1995 USE SYNTHETIC LUBRICANT $847 $2,867 Implemented
SF0068 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,062 $2,666 Implemented
SF0068 # 03 Y:1995 03 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $12,233 $1,000 Implemented
SF0068 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $2,174 $3,300 Implemented
SF0068 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,248 $20,160 Implemented
MS0035 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,824 $4,949 Not Implemented
MS0035 # 07 Y:1995 07 1995 RECOVER WASTE HEAT FROM EQUIPMENT $18,198 $32,850 Not Implemented
MS0035 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $817 $50 Implemented
MS0035 # 02 Y:1995 02 1995 OPTIMIZE PLANT POWER FACTOR $5,164 $2,130 Implemented
MS0035 # 04 Y:1995 04 1995 SHUT OFF PILOTS IN STANDBY EQUIPMENT $678 $20 Not Implemented
MS0035 # 05 Y:1995 05 1995 INSTALL TIMERS AND/OR THERMOSTATS $2,158 $5,000 Not Implemented
MS0035 # 03 Y:1995 03 1995 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $11,921 $12,146 Not Implemented
TN0553 # 02 Y:1995 02 1995 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,313 $1,320 Implemented
TN0553 # 01 Y:1995 01 1995 SHUT OFF PILOTS IN STANDBY EQUIPMENT $810 $0 Implemented
TN0553 # 03 Y:1995 03 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $853 $0 Implemented
TN0553 # 04 Y:1995 04 1995 USE DEMAND CONTROLLER OR LOAD SHEDDER $14,284 $20,800 Not Implemented
MS0032 # 05 Y:1995 05 1995 SHUT OFF PILOTS IN STANDBY EQUIPMENT $1,583 $20 Implemented
MS0032 # 04 Y:1995 04 1995 OPTIMIZE PLANT POWER FACTOR $674 $1,800 Not Implemented
MS0032 # 03 Y:1995 03 1995 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $2,758 $5,700 Not Implemented
MS0032 # 01 Y:1995 01 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $973 $75 Implemented
MS0032 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,838 $11,514 Not Implemented
CO0334 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,140 $520 Implemented