Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,525
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0385 # 01 Y:2011 | 01 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $1,423 | $3,996 | Implemented |
UM0385 # 02 Y:2011 | 02 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $390 | $10 | Not Implemented |
UM0385 # 03 Y:2011 | 03 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $18,202 | $11,500 | Not Implemented |
UM0385 # 04 Y:2011 | 04 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,717 | $4,500 | Not Implemented |
UM0385 # 05 Y:2011 | 05 | 2011 | BURN WOOD BY-PRODUCTS FOR HEAT | $6,704 | $78,500 | Not Implemented |
UM0385 # 06 Y:2011 | 06 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,820 | $3,172 | Not Implemented |
UM0385 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $48,155 | $21,000 | Not Implemented |
UM0382 # 01 Y:2011 | 01 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $252 | $1,000 | Not Implemented |
UM0382 # 02 Y:2011 | 02 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $87 | $10 | Not Implemented |
UM0382 # 03 Y:2011 | 03 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,453 | $1,000 | Not Implemented |
UM0382 # 04 Y:2011 | 04 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,843 | $2,200 | Not Implemented |
UM0382 # 05 Y:2011 | 05 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,115 | $2,800 | Not Implemented |
UM0382 # 06 Y:2011 | 06 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $17,682 | $21,309 | Not Implemented |
UM0382 # 07 Y:2011 | 07 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,797 | $31,000 | Not Implemented |
NC0419 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $967 | $25 | Implemented |
NC0419 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,212 | $2,582 | Not Implemented |
NC0419 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $50 | Implemented |
NC0419 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $363 | $100 | Implemented |
NC0419 # 05 Y:2011 | 05 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $873 | $50 | Implemented |
NC0419 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $139 | $517 | Implemented |
MI0198 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,683 | $55,919 | Implemented |
MI0198 # 02 Y:2010 | 02 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $37,497 | $39,695 | Not Implemented |
MI0198 # 03 Y:2010 | 03 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $17,892 | $2,000 | Implemented |
MI0198 # 04 Y:2010 | 04 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,048 | $13,338 | Implemented |
MI0198 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $5,576 | $14,400 | Implemented |