Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
220
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0089 # 05 Y:2005 | 05 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $26,400 | $0 | Implemented |
LM0089 # 06 Y:2005 | 06 | 2005 | MODIFY MATERIAL APPLICATION METHODS | $7,090 | $800 | Implemented |
LM0073 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,682 | $1,300 | Implemented |
LM0073 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,649 | $0 | Implemented |
LM0073 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,384 | $0 | Not Implemented |
LM0073 # 04 Y:2004 | 04 | 2004 | ADD AREA LIGHTING SWITCHES | $6,155 | $1,600 | Not Implemented |
LM0073 # 05 Y:2004 | 05 | 2004 | INSTALL SPECTRAL REFLECTORS / DELAMP | $784 | $0 | Implemented |
LM0073 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,570 | $1,093 | Implemented |
LM0073 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,911 | $3,520 | Not Implemented |
LM0073 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,302 | $10,000 | Not Implemented |
LM0073 # 09 Y:2004 | 09 | 2004 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $27,520 | $4,000 | Implemented |
LM0073 # 10 Y:2004 | 10 | 2004 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $207,176 | $0 | Not Implemented |
LM0073 # 11 Y:2004 | 11 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $10,400 | $1,562 | Implemented |
LM0073 # 12 Y:2004 | 12 | 2004 | DEVELOP STANDARD OPERATING PROCEDURES | $33,857 | $9,860 | Not Implemented |
SF0261 # 06 Y:2003 | 06 | 2003 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $63,661 | $36,750 | Not Implemented |
SF0261 # 05 Y:2003 | 05 | 2003 | BURN WOOD BY-PRODUCTS FOR HEAT | $25,467 | $4,500 | Implemented |
SF0261 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,010 | $33,679 | Not Implemented |
SF0261 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $4,341 | $485 | Not Implemented |
SF0261 # 02 Y:2003 | 02 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $3,924 | $52 | Not Implemented |
SF0261 # 01 Y:2003 | 01 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $10,012 | $0 | Implemented |
LM0043 # 05 Y:2002 | 05 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $284 | $331 | Not Implemented |
LM0043 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $1,365 | Implemented |
LM0043 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,494 | $2,354 | Not Implemented |
LM0043 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,002 | $250 | Implemented |
LM0043 # 06 Y:2002 | 06 | 2002 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $27,000 | $19,260 | Not Implemented |