Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,564
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0523 # 02 Y:2007 | 02 | 2007 | REPOSITION OVEN WALLS TO REDUCE HEATED SPACE | $11,700 | $500 | Implemented |
AM0523 # 03 Y:2007 | 03 | 2007 | PAY UTILITY BILLS ON TIME | $4,560 | $0 | Implemented |
AM0523 # 04 Y:2007 | 04 | 2007 | KEEP LAMPS AND REFLECTORS CLEAN | $1,810 | $0 | Implemented |
AM0523 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $390 | $6 | Implemented |
AM0523 # 06 Y:2007 | 06 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $340 | $0 | Implemented |
AM0523 # 07 Y:2007 | 07 | 2007 | USE SYNTHETIC LUBRICANT | $205 | $0 | Implemented |
MS0305 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $48,733 | $70,000 | Not Implemented |
MS0305 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,385 | $16,886 | Implemented |
MS0305 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,851 | $244 | Implemented |
IA0393 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,020 | $541 | Implemented |
IA0393 # 02 Y:2006 | 02 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $578 | $5,251 | Not Implemented |
IA0393 # 03 Y:2006 | 03 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $762 | $0 | Implemented |
IA0393 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,978 | $0 | Implemented |
IA0393 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,479 | $16,536 | Implemented |
IA0393 # 06 Y:2006 | 06 | 2006 | ADD AREA LIGHTING SWITCHES | $1,508 | $1,200 | Implemented |
IA0393 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $636 | $1,155 | Implemented |
IA0393 # 08 Y:2006 | 08 | 2006 | MODIFY STARTUP/SHUTDOWN TIMES | $5,715 | $0 | Implemented |
SD0380 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,026 | $3,850 | Not Implemented |
SD0380 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,324 | $220 | Not Implemented |
SD0380 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,495 | $4,550 | Not Implemented |
SD0380 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,418 | $2,325 | Not Implemented |
SD0380 # 05 Y:2006 | 05 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $459 | $3,193 | Not Implemented |
LM0105 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $638 | $0 | Not Implemented |
LM0105 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,156 | $960 | Implemented |
LM0105 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,197 | $250 | Implemented |