Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,525

matching recommendations
Reset
SIC 25 Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0287 # 10 Y:2005 10 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $658 $0 Implemented
BD0287 # 11 Y:2005 11 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $568 $440 Not Implemented
BD0287 # 12 Y:2005 12 2005 USE SYNTHETIC LUBRICANT $564 $600 Implemented
BD0287 # 13 Y:2005 13 2005 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,040 $140 Implemented
BD0285 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,090 $2,695 Implemented
BD0285 # 02 Y:2005 02 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,976 $4,080 Implemented
BD0285 # 03 Y:2005 03 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,695 $0 Implemented
BD0285 # 04 Y:2005 04 2005 INSTALL OCCUPANCY SENSORS $995 $675 Not Implemented
BD0285 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $487 $900 Implemented
BD0285 # 06 Y:2005 06 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $488 $0 Implemented
BD0285 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $370 $360 Implemented
BD0285 # 08 Y:2005 08 2005 CONTRACT A WOOD PALLET RECYCLING COMPANY $11,600 $480 Implemented
BD0285 # 09 Y:2005 09 2005 MINIMIZE WATER USAGE $3,135 $1,320 Not Implemented
BD0285 # 10 Y:2005 10 2005 CHANGE OPERATING CONDITIONS $2,898 $2,500 Not Implemented
NC0311 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,798 $14,107 Implemented
NC0311 # 02 Y:2005 02 2005 REPROCESS SPENT OILS ON SITE FOR RE-USE $15,075 $4,000 Not Implemented
NC0311 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,158 $100 Implemented
NC0311 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $23,954 $750 Implemented
NC0311 # 05 Y:2005 05 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $4,051 $7,280 Not Implemented
NC0311 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,142 $3,555 Implemented
NC0311 # 07 Y:2005 07 2005 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS $242,500 $150,000 Not Implemented
NC0311 # 08 Y:2005 08 2005 INSTALL SYSTEM TO COLLECT SCRAP $6,250 $10,000 Implemented
MA0572 # 01 Y:2005 01 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $39,353 $1,300 Implemented
MA0572 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $15,571 $4,080 Implemented
MA0572 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,380 $81,540 Implemented