Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
354
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0189 # 02 Y:2001 | 02 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,426 | $2,725 | Not Implemented |
MS0189 # 03 Y:2001 | 03 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,255 | $1,550 | Not Implemented |
MS0189 # 04 Y:2001 | 04 | 2001 | DISCONNECT BALLASTS | $286 | $540 | Implemented |
MS0189 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $171 | $128 | Implemented |
MS0189 # 06 Y:2001 | 06 | 2001 | COMBINE UTILITY METERS | $114 | $212 | Not Implemented |
MS0189 # 07 Y:2001 | 07 | 2001 | INSULATE BARE EQUIPMENT | $78 | $112 | Implemented |
MS0189 # 08 Y:2001 | 08 | 2001 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,638 | $4,046 | Implemented |
MS0189 # 09 Y:2001 | 09 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $57,988 | $72,000 | Not Implemented |
MS0189 # 10 Y:2001 | 10 | 2001 | AUTOMATE FINISHING PROCESS | $98,125 | $100,000 | Not Implemented |
MS0183 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,236 | $8,235 | Not Implemented |
MS0183 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,000 | $190 | Implemented |
MS0183 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $142 | $230 | Not Implemented |
MS0183 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $711 | $2,074 | Not Implemented |
MS0183 # 05 Y:2001 | 05 | 2001 | CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING | $1,957 | $432 | Not Implemented |
MS0183 # 06 Y:2001 | 06 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,296 | $50 | Not Implemented |
MS0182 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PLANT POWER FACTOR | $2,138 | $2,205 | Not Implemented |
MS0182 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,201 | $427 | Implemented |
MS0182 # 03 Y:2001 | 03 | 2001 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $647 | $54 | Implemented |
MS0182 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $195 | Not Implemented |
MS0182 # 05 Y:2001 | 05 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $91 | $0 | Implemented |
MS0181 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $282 | $107 | Not Implemented |
MS0181 # 02 Y:2001 | 02 | 2001 | USE SYNTHETIC LUBRICANT | $177 | $132 | Not Implemented |
MS0181 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $672 | $104 | Implemented |
MS0181 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,627 | $0 | Not Implemented |
MS0181 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,332 | $2,100 | Not Implemented |