Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,525
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0154 # 01 Y:2000 | 01 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,846 | $0 | Implemented |
MS0154 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,801 | $709 | Not Implemented |
MS0154 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $188 | $205 | Not Implemented |
MS0154 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $584 | $198 | Implemented |
MS0154 # 05 Y:2000 | 05 | 2000 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,134 | $361 | Not Implemented |
MS0154 # 06 Y:2000 | 06 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $880 | $50 | Implemented |
TN0652 # 01 Y:1999 | 01 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $189,625 | $28,000 | Implemented |
TN0652 # 02 Y:1999 | 02 | 1999 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $34,710 | $27,240 | Not Implemented |
TN0652 # 03 Y:1999 | 03 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $23,000 | $60,500 | Implemented |
TN0652 # 04 Y:1999 | 04 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $18,000 | $49,200 | Implemented |
TN0652 # 05 Y:1999 | 05 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $5,625 | $16,000 | Implemented |
TN0652 # 06 Y:1999 | 06 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $4,000 | $100 | Implemented |
TN0652 # 07 Y:1999 | 07 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,700 | $4,000 | Implemented |
TN0652 # 08 Y:1999 | 08 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $96,250 | $400,000 | Not Implemented |
TN0652 # 09 Y:1999 | 09 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $28,970 | $300 | Not Implemented |
TN0652 # 10 Y:1999 | 10 | 1999 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $16,210 | $10,000 | Not Implemented |
MS0153 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,745 | $1,384 | Implemented |
MS0153 # 02 Y:2000 | 02 | 2000 | OPTIMIZE PLANT POWER FACTOR | $4,678 | $4,725 | Implemented |
MS0153 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,254 | $322 | Not Implemented |
MS0153 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,107 | $1,552 | Implemented |
MS0153 # 05 Y:2000 | 05 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $9,517 | $3,600 | Not Implemented |
MS0153 # 06 Y:2000 | 06 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,003 | $27,300 | Not Implemented |
MS0153 # 07 Y:2000 | 07 | 2000 | USE RE-USABLE FILTERS | $735 | $560 | Not Implemented |
MS0153 # 08 Y:2000 | 08 | 2000 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $10,573 | $3,540 | Implemented |
HO0223 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $952 | $4,794 | Not Implemented |