Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
189
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0621 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,980 | $17,100 | Not Implemented |
TN0621 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,710 | $17,000 | Not Implemented |
TN0621 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,400 | $0 | Not Implemented |
TN0621 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $655 | $0 | Not Implemented |
SF0128 # 11 Y:1997 | 11 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $630 | $195 | Implemented |
SF0128 # 04 Y:1997 | 04 | 1997 | USE PHOTOCELL CONTROLS | $1,929 | $1,500 | Not Implemented |
SF0128 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $434 | $1,440 | Not Implemented |
SF0128 # 03 Y:1997 | 03 | 1997 | ADD AREA LIGHTING SWITCHES | $535 | $850 | Not Implemented |
SF0128 # 09 Y:1997 | 09 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $253 | $25 | Implemented |
SF0128 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $500 | $742 | Implemented |
SF0128 # 02 Y:1997 | 02 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,849 | $3,760 | Not Implemented |
SF0128 # 05 Y:1997 | 05 | 1997 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $970 | $1,500 | Not Implemented |
SF0128 # 10 Y:1997 | 10 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $521 | $300 | Implemented |
SF0128 # 06 Y:1997 | 06 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,094 | $8,069 | Not Implemented |
SF0128 # 08 Y:1997 | 08 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,081 | $12,944 | Implemented |
SF0128 # 12 Y:1997 | 12 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $36 | $0 | Implemented |
IA0179 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $167 | $166 | Implemented |
IA0179 # 06 Y:1997 | 06 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $475 | $75 | Not Implemented |
IA0179 # 04 Y:1997 | 04 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,599 | $1,019 | Implemented |
IA0179 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,405 | $525 | Not Implemented |
IA0179 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,789 | $1,842 | Implemented |
IA0179 # 02 Y:1997 | 02 | 1997 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $2,253 | $2,697 | Implemented |
IA0179 # 01 Y:1997 | 01 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,185 | $8,000 | Not Implemented |
MS0098 # 06 Y:1997 | 06 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $28,149 | $2,288 | Not Implemented |
MS0098 # 05 Y:1997 | 05 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,885 | $23,672 | Not Implemented |