Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,631
matching recommendationsSIC | 251 | Household Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0399 # 05 Y:1990 | 05 | 1990 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $6,555 | $16,100 | Not Implemented |
TN0399 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,873 | $185 | Implemented |
TN0399 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $96 | Implemented |
TN0399 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $813 | $680 | Implemented |
TN0399 # 09 Y:1990 | 09 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $583 | $210 | Implemented |
TN0399 # 10 Y:1990 | 10 | 1990 | OPTIMIZE PLANT POWER FACTOR | $4,690 | $5,900 | Not Implemented |
TN0401 # 01 Y:1990 | 01 | 1990 | BURN WOOD BY-PRODUCTS FOR HEAT | $15,125 | $58,640 | Not Implemented |
TN0401 # 02 Y:1990 | 02 | 1990 | CLOSE OFF UNNEEDED STEAM LINES | $3,385 | $0 | Implemented |
TN0401 # 03 Y:1990 | 03 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $2,853 | $770 | Implemented |
TN0401 # 04 Y:1990 | 04 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,117 | $30,000 | Implemented |
TN0401 # 05 Y:1990 | 05 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $9,859 | $28,302 | Not Implemented |
TN0401 # 06 Y:1990 | 06 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,021 | $1,140 | Implemented |
TN0401 # 07 Y:1990 | 07 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $978 | $200 | Implemented |
TN0401 # 08 Y:1990 | 08 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,039 | $4,000 | Not Implemented |
TN0401 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,423 | $1,230 | Not Implemented |
TN0355 # 01 Y:1988 | 01 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,038 | $18,500 | Not Implemented |
TN0355 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,104 | $750 | Implemented |
TN0355 # 03 Y:1988 | 03 | 1988 | KEEP LAMPS AND REFLECTORS CLEAN | $9,501 | $19,134 | Not Implemented |
TN0355 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,015 | $4,840 | Implemented |
TN0355 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,400 | $0 | Implemented |
TN0355 # 06 Y:1988 | 06 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,943 | $1,220 | Implemented |
TN0355 # 07 Y:1988 | 07 | 1988 | DISCONNECT BALLASTS | $1,320 | $2,321 | Implemented |
TN0355 # 08 Y:1988 | 08 | 1988 | IMPROVE LUBRICATION PRACTICES | $1,071 | $0 | Implemented |
TN0355 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,046 | $360 | Not Implemented |
AT0116 # 01 Y:1988 | 01 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $807 | $1,596 | Implemented |