Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsSIC | 251 | Household Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0186 # 04 Y:2017 | 04 | 2017 | REDUCE EXCESS STEAM BLEEDING | $38,730 | $4,000 | Not Implemented |
TT0186 # 01 Y:2017 | 01 | 2017 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $684,912 | $1,500,000 | Not Implemented |
TT0186 # 06 Y:2017 | 06 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $587 | $1,123 | Not Implemented |
TT0186 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $44,574 | $5,800 | Implemented |
TT0186 # 07 Y:2017 | 07 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $543 | $200 | Not Implemented |
TT0186 # 05 Y:2017 | 05 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $12,015 | $33,000 | Implemented |
TT0186 # 02 Y:2017 | 02 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $78,651 | $90,000 | Implemented |
TT0108 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,126 | $10,709 | Implemented |
TT0108 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,110 | $1,110 | Not Implemented |
TT0108 # 04 Y:2013 | 04 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $4,000 | $980 | Implemented |
TT0108 # 02 Y:2013 | 02 | 2013 | CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS | $5,367 | $8,075 | Not Implemented |
MZ0102 # 06 Y:2012 | 06 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,370 | $2,270 | Implemented |
MZ0102 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $930 | $700 | Implemented |
MZ0102 # 02 Y:2012 | 02 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,776 | $10,060 | Not Implemented |
MZ0102 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,326 | $16,800 | Implemented |
MZ0102 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,444 | $0 | Implemented |
MZ0102 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,327 | $2,000 | Implemented |
TN0621 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $655 | $0 | Not Implemented |
TN0621 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,400 | $0 | Not Implemented |
TN0621 # 04 Y:1997 | 04 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $8,175 | $9,600 | Not Implemented |
TN0621 # 01 Y:1997 | 01 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $24,470 | $4,300 | Not Implemented |
TN0621 # 02 Y:1997 | 02 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $17,500 | $17,900 | Implemented |
TN0621 # 03 Y:1997 | 03 | 1997 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $14,220 | $27,690 | Not Implemented |
TN0621 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,710 | $17,000 | Not Implemented |
TN0621 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,980 | $17,100 | Not Implemented |