Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

155

matching recommendations
Reset
SIC 2514 Metal Household Furniture
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0299 # 16 Y:2002 16 2002 INCREASE USE OF AUTOMATION $16,500 $0 Not Implemented
OK0604 # 01 Y:2000 01 2000 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $7,686 $4,275 Implemented
OK0604 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,442 $1,900 Not Implemented
OK0604 # 03 Y:2000 03 2000 $24,537 $26,122 Not Implemented
OK0604 # 04 Y:2000 04 2000 $18,577 $1,801 Implemented
OK0604 # 05 Y:2000 05 2000 $70,200 $47,500 Implemented
UM0134 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,206 $1,000 Not Implemented
UM0134 # 02 Y:1999 02 1999 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $11,967 $2,000 Not Implemented
UM0134 # 03 Y:1999 03 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $27,764 $36,550 Not Implemented
UM0134 # 04 Y:1999 04 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $1,800 $0 Not Implemented
UM0134 # 05 Y:1999 05 1999 $944,916 $200,000 Not Implemented
NC0035 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,391 $1,620 Implemented
NC0035 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,132 $700 Not Implemented
NC0035 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,131 $500 Not Implemented
NC0035 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $824 $0 Implemented
NC0035 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,711 $1,085 Not Implemented
NC0035 # 06 Y:1994 06 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $664 $820 Not Implemented
NC0035 # 07 Y:1994 07 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,987 $17,200 Not Implemented
NC0035 # 08 Y:1994 08 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,639 $2,000 Not Implemented
NC0035 # 09 Y:1994 09 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,960 $9,280 Implemented
NC0035 # 10 Y:1994 10 1994 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $6,023 $3,650 Not Implemented
UF0067 # 01 Y:1993 01 1993 USE POWER DURING OFF-PEAK PERIODS $3,864 $0 Not Implemented
UF0067 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,583 $4,808 Implemented
UF0067 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $522 $705 Not Implemented
UF0067 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $347 $675 Not Implemented