Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
SIC 252 Office Furniture
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0228 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,861 $6,210 Not Implemented
MS0228 # 05 Y:2003 05 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $323 $0 Implemented
MS0228 # 06 Y:2003 06 2003 INSULATE BARE EQUIPMENT $90 $157 Not Implemented
MS0228 # 04 Y:2003 04 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,237 $1,210 Not Implemented
MS0228 # 03 Y:2003 03 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,499 $2,540 Implemented
MS0228 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,344 $276 Implemented
MS0211 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,516 $577 Implemented
MS0211 # 06 Y:2002 06 2002 $48,814 $175,000 Not Implemented
MS0211 # 04 Y:2002 04 2002 INSTALL TIMERS AND/OR THERMOSTATS $675 $472 Implemented
MS0211 # 05 Y:2002 05 2002 DISCONNECT BALLASTS $442 $255 Implemented
MS0211 # 01 Y:2002 01 2002 RECOVER WASTE HEAT FROM EQUIPMENT $2,096 $1,739 Not Implemented
MS0211 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $864 $2,540 Not Implemented
MS0170 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $400 $504 Implemented
MS0170 # 03 Y:2000 03 2000 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $29,773 $41,847 Implemented
MS0170 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,522 $296 Implemented
MS0166 # 06 Y:2000 06 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $11,439 $7,938 Not Implemented
MS0166 # 05 Y:2000 05 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $1,157 $376 Not Implemented
MS0166 # 04 Y:2000 04 2000 INSTALL TIMERS AND/OR THERMOSTATS $311 $472 Not Implemented
MS0166 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,903 $3,464 Not Implemented
MS0166 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $551 $222 Not Implemented
MS0166 # 01 Y:2000 01 2000 SHUT OFF PILOTS IN STANDBY EQUIPMENT $190 $70 Implemented
MS0166 # 07 Y:2000 07 2000 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $29,386 $2,399 Not Implemented
MS0104 # 05 Y:1998 05 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $3,224 $1,080 Not Implemented
MS0104 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $5,872 $12,115 Implemented
MS0104 # 02 Y:1998 02 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $12,499 $3,080 Not Implemented