Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

361

matching recommendations
Reset
SIC 2521 Wood Office Furniture
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0189 # 02 Y:1997 02 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,474 $20 Not Implemented
UL0189 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $111 $4,120 Not Implemented
IA0179 # 01 Y:1997 01 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $4,185 $8,000 Not Implemented
IA0179 # 02 Y:1997 02 1997 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $2,253 $2,697 Implemented
IA0179 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,789 $1,842 Implemented
IA0179 # 04 Y:1997 04 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,599 $1,019 Implemented
IA0179 # 05 Y:1997 05 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,405 $525 Not Implemented
IA0179 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $475 $75 Not Implemented
IA0179 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $167 $166 Implemented
AS0211 # 01 Y:1997 01 1997 INSTALL OCCUPANCY SENSORS $1,173 $1,725 Not Implemented
AS0211 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,090 $7,878 Not Implemented
AS0211 # 03 Y:1997 03 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $526 $30 Implemented
AS0211 # 04 Y:1997 04 1997 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $1,328 $90 Not Implemented
AS0211 # 05 Y:1997 05 1997 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,776 $2,985 Not Implemented
AS0211 # 06 Y:1997 06 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $21,316 $8,000 Not Implemented
AS0211 # 07 Y:1997 07 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $659 $1,981 Not Implemented
AS0211 # 08 Y:1997 08 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $326 $60 Not Implemented
AS0211 # 09 Y:1997 09 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $750 $30 Not Implemented
AS0211 # 10 Y:1997 10 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $9,840 $60 Not Implemented
AS0211 # 11 Y:1997 11 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $648 $30 Not Implemented
AS0210 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,771 $2,051 n/a
AS0210 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $562 $1,050 n/a
AS0210 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,457 $90 n/a
AS0210 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,284 $620 n/a
AS0210 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,173 $4,099 n/a