Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 2521 | Wood Office Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0073 # 05 Y:2015 | 05 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,166 | $4,202 | Not Implemented |
WM0073 # 17 Y:2015 | 17 | 2015 | INSTALL OCCUPANCY SENSORS | $133 | $268 | Not Implemented |
WM0073 # 16 Y:2015 | 16 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $125 | Implemented |
WM0073 # 15 Y:2015 | 15 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $471 | $130 | Not Implemented |
WM0073 # 14 Y:2015 | 14 | 2015 | INSTALL OCCUPANCY SENSORS | $520 | $100 | Not Implemented |
WM0073 # 13 Y:2015 | 13 | 2015 | USE SYNTHETIC LUBRICANT | $654 | $1,155 | Implemented |
WM0073 # 12 Y:2015 | 12 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,070 | $391 | Implemented |
WM0073 # 11 Y:2015 | 11 | 2015 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $15,300 | $5,570 | Not Implemented |
WM0073 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $134 | $268 | Not Implemented |
WM0073 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $288 | $100 | Implemented |
WM0073 # 08 Y:2015 | 08 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $423 | $380 | Implemented |
WM0073 # 07 Y:2015 | 07 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $974 | $527 | Not Implemented |
WM0073 # 06 Y:2015 | 06 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,049 | $132 | Implemented |
WM0073 # 04 Y:2015 | 04 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,673 | $334 | Implemented |
WM0073 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,465 | $25,360 | Not Implemented |
WM0073 # 02 Y:2015 | 02 | 2015 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $11,105 | $9,052 | Not Implemented |
WM0073 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,390 | $4,800 | Implemented |
SU0391 # 01 Y:2015 | 01 | 2015 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $9,598 | $5,243 | Implemented |
SU0391 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,885 | $9,310 | Not Implemented |
SU0391 # 07 Y:2015 | 07 | 2015 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $584 | $2,876 | Not Implemented |
SU0391 # 06 Y:2015 | 06 | 2015 | INSULATE BARE EQUIPMENT | $938 | $1,414 | Implemented |
SU0391 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,806 | $2,683 | Not Implemented |
SU0391 # 04 Y:2015 | 04 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $64,843 | $97,500 | Not Implemented |
SU0391 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,180 | $2,800 | Not Implemented |
SU0391 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $716 | $367 | Implemented |