IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

169

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0423 # 04 Y:1994 04 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,024 $400 Implemented
UD0423 # 06 Y:1994 06 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $920 $0 Implemented
UD0419 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $19,715 $13,400 Implemented
UD0419 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,200 $5,739 Implemented
UD0419 # 05 Y:1993 05 1993 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $81,110 $0 Implemented
UD0419 # 07 Y:1993 07 1993 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $89,581 $20,000 Implemented
UD0379 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $8,593 $9,000 Implemented
UD0379 # 03 Y:1992 03 1992 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $3,637 $750 Implemented
UD0321 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,217 $37,000 Implemented
UD0321 # 02 Y:1990 02 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,310 $7,500 Implemented
UD0321 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,760 $1,100 Implemented
UD0266 # 01 Y:1988 01 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,611 $600 Implemented
UD0266 # 02 Y:1988 02 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $462 $0 Implemented
UD0266 # 04 Y:1988 04 1988 REPAIR AND ELIMINATE STEAM LEAKS $21,603 $5,000 Implemented
UD0266 # 05 Y:1988 05 1988 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $23,169 $20,000 Implemented
UD0266 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,639 $11,475 Implemented
UD0266 # 07 Y:1988 07 1988 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $9,266 $30,000 Implemented
UD0253 # 01 Y:1988 01 1988 REDUCE VENTILATION AIR $2,007 $900 Implemented
UD0253 # 02 Y:1988 02 1988 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING $15,536 $20,000 Implemented
UD0253 # 03 Y:1988 03 1988 INSULATE BARE EQUIPMENT $875 $805 Implemented
UD0253 # 04 Y:1988 04 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,830 $8,000 Implemented
UD0253 # 05 Y:1988 05 1988 INSTALL STORM WINDOWS AND DOORS $804 $700 Implemented
UD0248 # 01 Y:1988 01 1988 COMBINE UTILITY METERS $1,427 $0 Implemented
UD0248 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,309 $400 Implemented